SENKO fireplaces
–
Instruction manual
27
figure 13
THE KEY
:
1.
Ceiling of fireproof material
2.
Insulation (carry out according to DIN 18160)
3.
Smoke uptake pipe made of steel sheets
4.
Sheet metal covering convection air chamber
5.
Heating insulation layer (rear side)
6.
Primary walling
7.
Protective wall of fireproof material or building
material of concrete/steel concrete
8.
Heating insulation layer (stone wool), 100
mm thick at minimum
9.
Primary air inlet for combustion
10.
Heating insulation layer (floor)
11.
Support plate
12.
Protective floor of fireproof material or
building material
13.
Non-inflammable base insulation (for wooden
floors)
14.
Concrete base (ash box guiding mechanism
thickness)
15.
Ash box
16.
Firebox door
17.
Opening for air circulation needed for firebox
glass door cleaning (when carrying out the
lining, leave the opening free for air
circulation)
18.
Bearing frame
19.
Decorative beam
20.
Hot air outlet grate
21.
Tubes for room heating air-through (free or
forced circulation)
22.
Flue damper handle
23.
Linings
24.
Bearing element
25.
60 mm heating insulation layer
26.
800 mm irradiation area