SENKO fireplaces
–
Instruction manual
6
1.3.
CHIMNEY
The fireplace is connected to the chimney via
standard 200 mm
diameter smoke venting pipe
, directly to the chimney or with the knee
45°
and extension pipe. It is necessary to execute the connection of the rosette
and the chimney tightly and impermeably. If the fireplace is separated from
the chimney opening, the extension
smoke inlet pipe must have an
appropriate incline and must not exceed 125 cm in length.
It is necessary to
leave the revision opening for chimney cleaning
,
connecting pipe and dome of soot. It is also necessary that the connection
elbow has the revision opening for cleaning on it.
We also advise
to
equip the chimney with solid material and
possible condensation products collection chamber
and to install the
chamber in question beneath the smoke channel inlet, in a manner which
allows easy access and inspection via impermeable door.
1.3.1. CHIMNEY CAP
Chimney cap must fulfill the following prerequisites:
identical internal cross-section
to that of the chimney,
operational
exit cross-section no less than the double inner
cross-section of the chimney
,
constructed
to prevent rain, snow, leaves and other foreign
bodies from entering
the chimney,
constructed
to enable expulsion of combustion products in
case of wind
from any direction and incline,