SENKO fireplaces
–
Instruction manual
31
The door must be opened slowly. After adding the fuel, close the door
slowly.
Open the primary air automatic regulator to decrease the time
of fuel combustion.
Once the fuel starts burning, adjust the primary air automatic
regulator to a desired position
in accordance with
chapter 5.1
.
Vent damper on the chimney outlet, MUST BE opened before
opening the firebox door !
5.2.4. FEEDING IN TRANSITION PERIOD
During the transition period, i.e.
when outdoor temperatures are
higher
, sudden increase in outdoor temperature can
cause chimney
malfunction
(decreased chimney flue draught) resulting with not all flue
gases being expelled into the atmosphere.
It is therefore recommended to
use
less fuel and smaller logs
during
the transition period in order to achieve a more lively flame, as well as to
adjust the primary air volume
in order to improve the expulsion of flue
gases from the chimney.
5.2.5. SPACE HEATING
Tubes (10)
are embedded in the dome (11)
, through which passes
the air for space heating.
Air can circulate natural and can also forcibly,
installing the fan and routers.