6.9.14
ETR 290 — Service thresh.
The
Service thresholds
make it possible to define detailed conditions for alarm triggering on a per-
service basis. There is one predefined service threshold template that cannot be edited by the operator:
Default
. The Default service threshold template contains no service definitions and will therefore not
alter alarming for any service.
By associating scheduling templates to service threshold templates it is possible to disable alarming at
pre-selected time intervals. Scheduling templates are defined in the
view and will
be available from the schedule drop-down menu.
In the ‘Service Thresholds’ table, the ‘Refs’ column shows how many streams are associated with each
threshold template. Thresholds are associated with each stream in the
view.
There are two different ways of creating user-defined thresholds. To create a new threshold template from
scratch the operator should click the
Add new threshold group
button. A pop-up window will appear
allowing the user to assign a name and value to the new threshold and define the alarm conditions.
Another way of creating a user-defined threshold template is by highlighting one of the templates already
defined and then click the
Duplicate selected
button.
Deleting a service threshold template is done by highlighting the template that should be removed and
clicking
Delete selected
. Note that if the deleted threshold template was assigned to a stream being
monitored, the new threshold template for that stream will default to the
Default
template.
The settings
Service checks
and
Content check
in the ETR threshold template controls whether or not
to report alarms based on the service threshold template parameters. Please note that content check
alarming (freeze-frame and color-freeze) are disabled in all default ETR threshold templates.
VB3xx 10G Probe User’s Manual version 5.3
151
Summary of Contents for VB330
Page 1: ...VB3xx 10G Probes Applies to software release v5 3 Form 8046E February 2017...
Page 7: ...F Appendix Restoring probe factory defaults 203 VB3xx 10G Probe User s Manual version 5 3 7...
Page 29: ...VB3xx 10G Probe User s Manual version 5 3 29...
Page 30: ...6 THE 10G PROBE GRAPHICAL USER INTERFACE 30 VB3xx 10G Probe User s Manual version 5 3...
Page 101: ...VB3xx 10G Probe User s Manual version 5 3 101...