![Sencore VB330 User Manual Download Page 63](http://html1.mh-extra.com/html/sencore/vb330/vb330_user-manual_1239233063.webp)
To add a threshold template to the list click the
Add new threshold
button. This will open the
Edit
threshold
pop-up view, allowing the user to define threshold parameters. A threshold template entry can
be selected by clicking the threshold template; the list entry will be highlighted. Several list entries can
be selected by using regular
Ctrl + click
functionality. Clicking the
Duplicate selected
button will open
the
Edit threshold
pop-up view with all threshold template parameters duplicated, except the threshold
template name. Clicking
Delete selected
will delete the highlighted list entry. Clicking
Edit selected
will
open the
Edit threshold
pop-up view associated with the highlighted threshold template. Batch editing
is supported. Select the threshold templates and click the
Edit selected
button. Parameters differing
between templates will be indicated in the
Edit selected
pop-up view by an asterisk wildcard symbol.
The search field in the upper right corner of the view allows the user to type a text string, and the threshold
list is updated to display only thresholds matching the specified text.
To disable a threshold alarm, set the threshold value to –1. This does
not
apply for
Manifest XML size
.
Threshold preset
Name:
The threshold template name defined by the user.
Refs:
The number of channels associated with the threshold template
Download speed error:
The maximum allowed difference between profile bitrate and download
bitrate (%). If the difference exceeds the threshold value a bitrate error
alarm will be raised.
Download speed warn:
The maximum allowed difference between profile bitrate and download
bitrate (%). If the difference exceeds the threshold value a bitrate error
warning will be raised.
Actual bitrate min:
The minimum allowed bitrate when measured actual bitrate is compared to
profile bitrate (%). If the actual bitrate goes below the threshold an actual
bitrate alarm will be raised.
Actual bitrate max:
The maximum allowed bitrate when measured actual bitrate is compared
to profile bitrate (%). If the actual bitrate exceeds the threshold an actual
bitrate alarm will be raised.
Sequence age:
The maximum time a manifest can remain unchanged before a manifest
age alarm is raised.
Manifest XML size:
The maximum detected size of the manifest before a manifest size alarm
is raised.
Min. profiles:
Minimum number of profiles in the selected channel before an alarm is
raised.
VB3xx 10G Probe User’s Manual version 5.3
63
Summary of Contents for VB330
Page 1: ...VB3xx 10G Probes Applies to software release v5 3 Form 8046E February 2017...
Page 7: ...F Appendix Restoring probe factory defaults 203 VB3xx 10G Probe User s Manual version 5 3 7...
Page 29: ...VB3xx 10G Probe User s Manual version 5 3 29...
Page 30: ...6 THE 10G PROBE GRAPHICAL USER INTERFACE 30 VB3xx 10G Probe User s Manual version 5 3...
Page 101: ...VB3xx 10G Probe User s Manual version 5 3 101...