SCTE 35 requires a license for the probe and also an ETR 290 engine to connect it to.
The SCTE 35 option enables monitoring of SCTE 35 events of all streams captured by the ETR engines.
It is recommended to one ETR engine dedicated to each SCTE 35 streams to get continuous monitoring.
The SCTE 35 option enables monitoring of SCTE 35 events of all streams captured by the ETR engines.
The stream list parameters
Stream name:
Name specified by the user when adding a multicast or tuning.
Interface:
The input source of the transport stream.
Services incl. SCTE 35:
The number of services in the transport stream which has SCTE 35
information.
Events:
The number of SCTE 35 events occurred in a transport stream.
Time since last event:
The time since last SCTE 35 event specified in seconds, minutes, hours
or days.
If an ETR engine is monitoring a transport stream containing SCTE 35 information, the current stream
will be added to the list in the SCTE 35 menu. By pressing the blue information button a new pop-up will
show up, the pop-up will give specific information about events in the specified transport stream.
The event information list parameters:
Parameter
Description
Time:
When the event occurred.
Service ID:
The ID of the service for which the event applies.
Service name:
The name of the service for which the event applies.
PID:
The PID carrying the SCTE 35 information. A service can have multiple SCTE
35 PIDs signaled in the PMT table.
Splice command:
The type of the splice command.
Event ID:
Id of the specific event.
Canceled indicator:
If set it indicates that this splice message cancels a previously sent splice
message.
Switch mode:
Specifies whether it is a splice in (switch to local content/ads) or splice out
event (switch back to the audio/video in the stream).
Splice mode:
Specifies whether the splice message applies to the entire service (Program
splice mode) or individual PID(s).
Duration:
The time when a splice occurred to its end.
Tier:
Specifies which tier group are to use this splice message. Multiple splice
messages can be sent addressed to different tier groups to allow switching at
different times.
When pressing the information button for a specific event a new window will pop-up with detailed
information about the event. The pop-up will show a log of the SCTE 35 events signaled for the specified
130
VB3xx 10G Probe User’s Manual version 5.3
Summary of Contents for VB330
Page 1: ...VB3xx 10G Probes Applies to software release v5 3 Form 8046E February 2017...
Page 7: ...F Appendix Restoring probe factory defaults 203 VB3xx 10G Probe User s Manual version 5 3 7...
Page 29: ...VB3xx 10G Probe User s Manual version 5 3 29...
Page 30: ...6 THE 10G PROBE GRAPHICAL USER INTERFACE 30 VB3xx 10G Probe User s Manual version 5 3...
Page 101: ...VB3xx 10G Probe User s Manual version 5 3 101...