Freeze-frame status:
If the probe has been licensed with the Content Extraction and Alarming
option, status bulbs are displayed indicating the current freeze-frame and
color-freeze status for the streams.
White:
Unknown (typically due to the VB330 being unable to decode video)
Grey:
freeze-frame detection is disabled.
Green:
freeze-frame detection is enabled, no freeze-frame is detected.
Yellow:
freeze-frame detection is enabled. Two consecutive equal frames
have been detected, but the freeze-frame error timeout value has not been
exceeded.
Red:
freeze-frame is enabled. Freeze-frame has been detected and the
freeze-frame error timeout value has been exceeded, thus resulting in an
alarm.
The
Thumbs Details
pop-up view is accessed by clicking a thumb in the
Thumb overview
view. For
more information about the details displayed in the
Thumbs Details
pop-up see chapter 6.4 for multicast
streams, and chapter 6.3.2 for OTT channels.
Clicking the
Close
button will close the view.
6.1.4