Min bitrate error:
Number of seconds the bitrate can fall below the error-threshold before a
VBC alarm is generated
ETR Pri 1 errors:
ETR error seconds are not relevant for the VB330 10G Probe
ETR Pri 2 errors:
ETR error seconds are not relevant for the VB330 10G Probe
ETR Pri 3 errors:
ETR error seconds are not relevant for the VB330 10G Probe
ETR other errors:
ETR error seconds are not relevant for the VB330 10G Probe
ETR interface errors:
ETR error seconds are not relevant for the VB330 10G Probe
OTT transport errors:
Number of seconds with OTT transport related alarms
OTT HTTP errors:
Number of seconds with OTT HTTP related alarms
OTT XML errors:
Number of seconds with OTT XML related alarms
6.10.11
Setup — Scheduling
The
Setup — Scheduling
view enables definition of scheduling templates which are associated with
PIDs or services using the PID threshold or service threshold template system. This way it is possible to
mask alarms during selected time intervals, e.g. due to maintenance.
In the Schedule list table the ‘Refs’ column shows how many references exist for each scheduling
template. References to scheduling templates may be found in PID and service threshold templates.
The search field in the upper right corner of the view allows the user to type a text string and the schedule
list is updated to display only scheduling templates matching the specified text.
The predefined scheduling templates
Never
and
Always
result in alarms being masked never or always,
respectively. A new scheduling template is created by clicking the
Add new schedule
button. It is also
possible to copy an existing scheduling template by highlighting a schedule template and clicking the
Duplicate selected
button. The alarm masking intervals are defined for individual week days or for all
week days. Intervals are specified on the form hhmm–hhmm, for instance the interval 1200–1400 means
that alarm masking should start at noon and finish at 2 pm. Several alarm masking intervals may be
specified for each day using comma separation. To edit an existing scheduling template, highlight it and
click the
Edit selected
button. To delete a template, highlight it and click the
Delete selected
button.
176
VB3xx 10G Probe User’s Manual version 5.3
Summary of Contents for VB330
Page 1: ...VB3xx 10G Probes Applies to software release v5 3 Form 8046E February 2017...
Page 7: ...F Appendix Restoring probe factory defaults 203 VB3xx 10G Probe User s Manual version 5 3 7...
Page 29: ...VB3xx 10G Probe User s Manual version 5 3 29...
Page 30: ...6 THE 10G PROBE GRAPHICAL USER INTERFACE 30 VB3xx 10G Probe User s Manual version 5 3...
Page 101: ...VB3xx 10G Probe User s Manual version 5 3 101...