Alyseo 106
SELTA S.p.A
.
All rights reserved. No parts of this document can be reproduced, memorized into archive system or transmitted
in any shape or through any means without the previous authorization of SELTA S.p.A.
Configuration Interface
4-11
Alyseo 106 User Manual
720041008-A0-GB Issue 4
serial upgrade from serial line
Alyseo106# upgrade http……..(‘?’)
<text> URL of the latest version firmware
Alyseo106# upgrade serial……(‘?’)
<ENTER> no further known parameters
The updating of the firmware of Alyseo 106 is potentially dangerous and a time within 2 and 4
minutes is required. During this operation, the terminal must not switched off and the operation
must be never stopped for any reason.
4.5.2.9 “application” menu
Alyseo106# application
IWF ATM-FR Inter Working Function
CF ATM Cell Forwarding Function
<enter> Show actual type of application
Through this configuration, it is possible to select the terminal application between Interworking
Function and Cell Forwarding.
The switching from one application to the other one causes the saving to ROM of the configuration
and the terminal reboot.
In the following paragraphs 4.5.2.10 and 4.5.2.11, the configuration parameters of the two
applications are reported.
4.5.2.10 “configure IWF” menu
Typing "configure IWF" or "configure CF" enters the InterWorking Function or the Cell Forwarding
configuration modality and, using help, we can see the available commands.
Ex:
Alyseo106 configure > (‘?’)
shdsl
SHDSL link parameter
frame_relay
Frame Relay
atm
ATM parameter
iwf
Create or modify connection FR-ATM
no
Negate a configuration item
cntrl
access control
show
show running configuration
done
Done configuration
The first 4 commands change level again and allow configuring the parameters of the SHDSL
physical level, of the ATM and Frame Relay higher levels and of the logic connection between
these.
Summary of Contents for Alyseo 106
Page 1: ...User Manual Alyseo 106 ...