-52-
List of menu modes
List of menu modes
Setting menu
Setting item
Setting value
Device ID
0 - 126
O
X
Baud Rate
9600, 19200, 38400 , 57600, 115200
X
O
Character Bit Length
7 , 8
X
O
Parity
None , Odd , Even
X
O
Stop Bit
1 , 2
X
O
Flow Control
RS/CS , Xon/Xoff
X
O
Character Code
Accept All , Ignore 4 Codes
X
O
Setting of Column
1 - ( maximum ) Columns *3
O
O
Control fore , Control back,
Reading Method
Direct , FACOM, Mark to mark,
O
O
Mark to mark
Magnification (display only
1 - 3 - 9 times (for top-end timing control)
when timing control types are selected)
2 - 3 - 9 times (for bottom-end timing control)
O
O
Min. Density Level
1 - 3 - 16
X
O
Density Balance
1 - 15
X
O
Reading Side (only when double-sided reading unit is installed) Single Side , Double Side
O
O
Hopper Mode
ADF , Manual Feed
O
O
Wait Time for Form
(displayed only when manual paper feeding mode is selected) None, 1 - 10 - 99s
O
O
Paper Weight
Automatic, 64g/m
2
, 84g/m
2
, 105g/m
2
, 128g/m
2
, 157g/m
2
O
O
Automatic Paper Discharge
Yes , No
O
X
Hopper Empty Detection
Yes , No
O
X
Timing Mark Error Detection
Yes , No
O
X
Double-Feeding Detection
Yes , No
O
O
Left End Skew Detection
Yes , No
O
O
Mark Skew Detection
Yes , No
O
O
Mark Skew Detection Run
(displayed only with mark skew detection)
1 - 155 Rows
O
O
Mark Skew Detection Level
(displayed only with mark skew detection)
1 - 3 - 16
O
X
Buzzer Control
Valid , Invalid
O
O
Buzzer Sound Adjustment
(displayed only when it's valid)
1 - 3 - 5
O
O
Buzzer SoundQuality Adjustment
(displayed only when it's valid)
1 - 2 - 3
O
O
Main Body Unit
(01-zz)
*4
O
O
Display
Front Reading Unit (01-zz)
*4
O
O
Version
Back Reading Unit
(only when double-sided reading unit is installed)
(01-zz)
*4
O
O
Type of Front
Sensor Pitch
(1/6, 0.2, 0.25, 0.3 inch)
*4
O
O
Reading Sensor Sensor of Type
(Infra Red, Visible Red, Violate)
*4
O
O
Type of Back Reaading Sensor Pitch
(1/6, 0.2, 0.25, 0.3 inch)
*4
O
O
Sensor (displayed only
for double-side unit)
Sensor of Type
(Infra Red, Visible Red, Violate)
*4
O
O
Type of Options Reading Sensor Unit (Single Side, Double Side)
*4
O
O
Feed Test 1
Start, Stop
O
O
Feed Test 2
Start, Stop
O
O
Paper Weight Test
Start
O
O
*1 Items displayed when SR-2300 mode is selected as the operating mode.
*2 Items displayed when SR-600 mode is selected as the operating mode.
*3 Maximum number of columns to read differs depending on device sensor pitch.
*4 Data in parenthesis will appear according to options installed in the device.
indicates factory default values.
Operation Mode
SR-2300 Mode , SR-600 Mode
*1
*2
Setting of
Interface
Setting of
Reading
Setting of
Error
Detection
Setting of
Buzzer
Display
Mode
Test mode
Summary of Contents for SR-2300
Page 70: ......