-28-
Data reading settings
B
Setting reading method
B
Setting reading method
Setting mark-reading method.
There are six kinds of reading methods: “Top-end timing control type,” “Bottom-end timing control
type,” “Direct under type,” “FACOM,” “Mark to mark type (without top-end margin reading),” and
“Mark to mark type (with top-end margin reading).”
When setting to “top-end timing control type” or “bottom-end timing control type,” you need to set
a control multiple number.
1.
Press the
MENU
switch to enter the menu mode.
2.
Use the
UP
and
DOWN
switches to select the following parameters,
and press the
FEED/ENTER
switch.
3.
Use the
UP
and
DOWN
switches to select [Reading Method] setting,
and press the
FEED/ENTER
switch.
(“ ” mark flashes in the first column of the first line on the LCD.)
4.
Use the
UP
and
DOWN
switches to set the value.
5.
Press the
FEED/ENTER
switch to save the setting value into memory.
(The flashing “ ” mark disappears from the LCD.)
6.
Keep pressing the
C
CLEAR/EXIT
switch until it returns to normal mode,
or press the
MENU
switch to return to normal mode.
Reading method
setting values
• Control Fore
• Control Back
• Direct
• FACOM
• Mark to Mark
• Mark to Mark
Summary of Contents for SR-2300