Data reading settings
B
Setting paper weight
B
Setting paper weight
Set the paper weight when double-feeding errors are detected.
Paper weight can be set according to the following six types: “Automatic,” “64g/m
2
,” “84g/m
2
,”
“105g/m
2
,” “128g/m
2
,” and “157g/m
2
.”
If it’s set to “Automatic,” the device detects double-feeding errors based on the weight of first
sheet read after the device is activated.
1.
Press the
MENU
switch to enter the menu mode.
2.
Use the
UP
and
DOWN
switches to select the following parameters,
and press the
FEED/ENTER
switch.
3.
Use the
UP
and
DOWN
switches to select [Paper Weight] setting,
and press the
FEED/ENTER
switch.
(“ ” mark flashes in the first column of the first line on the LCD.)
4.
Use the
UP
and
DOWN
switches to set the value.
5.
Press the
FEED/ENTER
switch to save the setting value into memory.
(The flashing “ ” mark disappears from the LCD.)
6.
Keep pressing the
C
CLEAR/EXIT
switch until it returns to normal mode,
or press the
MENU
switch to return to normal mode.
Paper weight
setting values
• Automatic
• 64g/m
2
• 84g/m
2
• 105g/m
2
• 128g/m
2
• 157g/m
2