HDOP Alarm
This function is used to show a warning when the received HDOP value exceeds
the Alarm Limit for more than 2 seconds. The default setting is 4 seconds.To
activate the HDOP Alarm:
[MENU] + "Alarms" + [ENTER] + "HDOP Alarm" + [ENTER]
Heading Alarm
This function is used to show a warning when the HDG sentence is not received
from a magnetic sensor reading.
[MENU] + "Alarms" + [ENTER] + "Heading Alarm" + [ENTER]
T-59.09/T-59.05:
Timer Alarm
The Timer Alarm is activated when the defined time is expired. Stops (Off) the
Timer Alarm counter or enter the Timer value (Hours Minutes Seconds Range
00:00:01 - 23:59:59).
[MENU] + "Alarms" + [ENTER] + "Timer Alarm" + [ENTER]
T-59.09/T-59.05:
Timer Direction
Set the Timer Direction UP or DOWN: when Timer Direction is set UP, the timer
start from zero and increases its value; the alarm is activated when the timer
reaches the Timer Value entered by the user. When Timer Direction is set DOWN,
the count-down starts from the value set by the user and decreases it's value.
The Alarm is activated when the Timer value goes to zero.
[MENU] + "Alarms" + [ENTER] + "Timer Direction" + [ENTER]
Grounding Alarm
To verify potential danger to navigation such as shallow water (depth areas),
intertidal areas, land, rocks, obstructions and shoreline constructions. The maps
are scanned every 10 seconds. If any of the above objects are found, the chart
plotter notifies the danger on a dedicated warning message box. The active
"Grounding Alarms" are shown in the Grounding Alarm Report page.
To activate the Grounding Alarm:
[MENU] + "Alarms" + [ENTER] + "Grounding Alarm" + [ENTER]
The chart plotter scans a sector in front of the boat. The direction is determined
by the current boat heading. You can select the length and its angle is 30 degrees.
The Grounding Alarm is switched Off by default after a Master Reset.
Grounding Alarm Range
To set the length of the sector to be detected among 0.25, 0.5, 1.0 Nm.
[MENU] + "Alarms" + [ENTER] + "Grounding Alarm Range" + [ENTER]
Grounding Alarm Report
To display the report of the dangerous objects currently detected.
[MENU] + "Alarms" + [ENTER] + "Grounding Alarm Report" + [ENTER]
When any of the searched objects is found in the scanned area, a tick marker is
printed on the relative box to identify which dangerous objects have been currently
detected. Once the alarm condition is no longer present, the relative tick marker is
removed.
NOTE
The alarm "No data available" is shown when no specific cartographic data are
found on the DATA MEDIA or when no DATA MEDIA is inserted.
Summary of Contents for Techmarine
Page 10: ...12 User Manual ...
Page 14: ...16 User Manual ...
Page 66: ...68 User Manual ...
Page 72: ...74 User Manual ...
Page 106: ...108 User Manual ...
Page 126: ...128 User Manual ...
Page 137: ...139 User Manual Video Output Connector C COM Connection ...
Page 138: ...140 User Manual ...
Page 144: ...146 User Manual ...