ASSEMBL
Y AND INST
ALLA
TION
POWER PLUG
Always connect the ground wire.
GROUND WIRE
CONVERSION ADAPTER
FIG. 6-7a
CONNECTION OF POWER AND GROUND
• Use the power supply equipped with an earth leakage breaker. Use of power
supply without such a breaker could result in fire if there is a current leakage.
• Have available a securely grounded indoor ground terminal. Without proper
grounding, customers could be electrocuted and product operations might not
always be stable.
• Do not expose the power cord or ground wire. If these are exposed, customers
could stumble over them, for instance, and easily damage them. Additionally,
if these lines are damaged, there could be a risk of electrical shock or short
circuit. Set these lines at locations where they will not interfere with customer
traffic, or attach covers to them.
• After laying out the power cord on the floor, be
sure to always protect it. If the power cord is left
exposed, it can easily be damaged, resulting in
electrical shock.
• When using the product’s AC unit ground
terminal, use ground wire with a circular terminal
as shown in the illustration, and establish ground
securely. Avoid indiscriminant grounding
operations such as use of wire with only its
sheath peeled off.
Hole diameter 6.4 mm
Terminal width 12 mm
If grounding has been established with the ground wire inside the power cord,
do not perform grounding with the AC unit ground terminal. Conversely, if the AC
unit ground terminal has been used for grounding, do not establish ground with
the ground wire in the power cord. Otherwise there could be faulty or erroneous
operations.
The accessory power cord has a ground wire
inside it.
Connect the power cord to the AC unit then
insert the power cord plug into a “power
outlet with ground terminal.” If there is
no “power outlet with ground terminal,”
be sure to establish ground by some other
means; for example, by connecting the AC
unit ground terminal to a ground wire with
a ground mechanism prepared separately.
If you use a conversion adapter sold on the
market to supply power, connect the ground
wire terminal of the adapter to a “securely
grounded ground terminal.” <For Taiwan>
Summary of Contents for 2SPICY
Page 106: ...PARTS LIST 101 18 3 ASSY BASE CABINET APA 1100 D 1 2 Diagram of cross section A A...
Page 112: ...PARTS LIST 107 18 8 ASSY BILLBOARD APA 1400 D 1 2...
Page 114: ...PARTS LIST 109 18 9 ASSY CENTER BOX APA 1500 D 1 2...
Page 132: ...PARTS LIST 127 18 24 ASSY BASE CABINET REAR APA 3100 D 1 2...
Page 134: ...PARTS LIST 129 18 25 REAR CABINET APA 3150 D 1 2...
Page 138: ...PARTS LIST 133 18 28 ASSY PEDAL APA 3200 D 1 2...
Page 143: ...138 PARTS LIST 18 32 CONTROL UNIT APA 2100 D 1 2...
Page 148: ...143 WIRING DIAGRAM 20 WIRING DIAGRAM D 1 3 20...
Page 149: ...144 WIRING DIAGRAM 20 D 2 3...
Page 150: ...145 WIRING DIAGRAM 20 D 3 3...