44 |
APPENDICES
This step leads on from the ‘Preliminary Cable Installation’
section, refer to “PRELIMINARY CABLE INSTALLATION” on
page 15. refer “MAINS AND COMMUNICATION CABLE
PATH” on page 21
UTILITY CONNECTIONS - MAINS CABLE INSTALLATION
Refer to information provided: “ELECTRICAL REQUIREMENTS”
on page 19.
ELECTRICAL REQUIREMENTS
WATER REQUIREMENTS
Refer to information provided: “WATER REQUIREMENTS” on
page 19.
INSTALLING THE DRAIN VALVE
Refer to information provided: “INSTALLING THE DRAIN
VALVE” on page 20.
CONNECTION TO MAINS WATER
Refer to information provided: “CONNECTION TO MAINS
WATER” on page 20.
APPENDIX – B ‘PIECE BY PIECE’ INSTALLATION
37. Plumb and connect all hoses to the manifold assemblies
as shown. Inner hoses (grey) are to be connected to the
upper manifold connection point. Outer hoses (blue) are
to be connected to the lower manifold connection point.
Important! It is imperative that the water distribution
hoses are connected correctly.
ILL2816-A
38. Transport the lid to the roof and reinstall. Tighten all 8 lid
screws uniformly and adequately.
39. Transport the side panel assemblies to the roof. To reinstall
all 4 side panel assemblies, rest the bottom lip of the side
panel on the tank guide ribs and engage the clips on an
angle as shown. Mate the top edge of the side panel with
the lid and press fit along the top surface. The panel will
lock into place with the lid. For installation of successive
side panels, ensure side ribs are neatly interfacing. These
can be pressed in with moderate force.
ILL2817-A
ILL2818-A
PRELIMINARY CABLE INSTALLATION
Your installation kit includes a control cable. It also includes a
Heat/Cool Duct Switch module which requires a separate mains
socket outlet. This outlet is best located near the socket outlet
supplying power to the installed gas heater, as the Heat/Cool
Duct Switch needs to be within 20 metres of the heater because
of the communications cables.
For Australia Only
The control cable will be routed through the corner recess slot
in the transition (as shown below) by the installer.
This cable
must be routed through this corner recess prior to the
cooler being mounted to the dropper.
ILL3029-A
40. Once all 4 side panels are fitted, refit all 8 side clips and all
4 top clips.
ILL2819-A