INSTALLATION
ILL2992-A
STEP 3 - COOLER, HEATER, HEAT COOL DUCT SWITCH
AND WALL CONTROL CONNECTION
Connect the 20m communication cables to the cooler control
and wall control as per below.
Damper Control output rating: 24VAC 1.6A.
If the supply cord is damaged, it must be replaced by a Seeley
service agent or similarly qualified person in order to avoid
hazard. Stranded conductors shall not be consolidated by lead-
tin soldering where they are subject to contact pressure, i.e
on terminal block. Interconnection cable to dampers shall use
cable that comply with the requirement of supply cord.
For 24VAC output use H05VV-F, 3 x 1.0mm cable only.
CAUTION:
The wall controller CONTROL IN and cooler
CONTROL OUT connections are SELV circuits and shall only
be connected to the corresponding SELV circuits on the wall
controller and heater control.
Wall Controller Options
Option
P/N
Description
Qty.
A
094298
MagIQtouch Wall Control
1
B
118369
MagIQtouch Wi-Fi Smart App Controller & 20m Cable
1
A
B
OR
CONTROLLER
(CABLE VERSION)
20M
CONTROLLER
(CABLE VERSION)
MAGIQTOUCH WIFI
SMART APP CONTROLLER
20M
20M
A
B
HEAT COOL
DUCT SWITCH
HEATER
DAMPERS
COOLER
DAMPERS
CW-6S
ILL3072-B
ILL3075-B
COMBINED COOLER AND HEATER WITH NO ZONES
Step 1 - Press ‘SETTINGS’ menu. If not displayed press
‘MORE’ to reveal the extra menu items.
MAGIQTOUCH WALL CONTROLLER
ILL2785-A
ILL1563-A
Step 2 - Select ‘COOLER’ tab and activate ‘DAMPER DELAY
MODULE’ button. Access code 7378 to activate.
ILL3022-A
Step 3 - Switch Damper Delay function to ‘ON’ and select time
for delay. ‘SAVE’ and exit when complete.
ILL3023-A