APPENDICES
SPAN = 10m MAX REFER NOTE D2
EXISTING SUPPORT
EXISTING SUPPORT
SEELEY INTERNATIONAL AIR CONDITIONING UNIT. REFER TO SEELEY INFORMATION FOR INSTALLATION DIMENSIONS AND GENERAL SPECIFICATIONS
TYPICAL TRUSS LAYOUT
NOT TO SCALE
1.0m MAX
DROPPER TO BE IN ACCORDANCE WITH THOSE SPECIFIED IN MANUFACTURER INSTALLATION MANUAL. REFER NOTE I10.
15° < D < 25° REFER NOTE D3
D
PROVIDE ADEQUATE FLASHING AROUND DUCT
DESCRIPTION
DATE
DRAWING SCALE
DRAFTER
ENGINEER
MANAGER
DRAWING TITLE
CLIENT
PROJECT
DATE
DRAWING NUMBER
REV
DO NOT SCALE FROM THIS DRAWING
ISSUE
PROJECT NUMBER
SHEET SIZE
INITIAL
REVISION
Consulting Engineers
452 Pulteney Street, Adelaide SA 5000
Telephone (08) 8231 2832 Facsimile (08) 8311 1742
www.mlei.com.au
TALENTED | APPROACHABLE | RESPONSIVE | PIONEERING
NOT FOR CONSTRUCTION
ISSUED FOR CERTIFICATION
GENERAL NOTES 1
NTS
S01
A3
C8
2017-6648
JT
TH
Apr-19
GENERIC AIR CONDITIONING ROOF MOUNT
SEELEY INTERNATIONAL
PG
GENERAL NOTES
THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL ENGINEER'S SOIL REPORT, ARCHITECTURAL AND OTHER CONSULTANTS DRAWINGS AND SPECIFICATIONS AND WRITTEN INSTRUCTIONS AS MAY BE ISSUED DURING THE COURSE OF THE CONTRACT.
G1
ALL DIMENSIONS, LEVELS ETC. SHALL BE CONFIRMED FROM THE ARCHITECT'S DRAWINGS AND / OR CHECKED FROM THE JOB.
G4
IF ANY DISCREPANCY OCCURS ON THE ENGINEER'S DRAWINGS OR BETWEEN DRAWINGS AND THE SPECIFICATION, THE DISCREPANCY MUST BE REFERRED TO THE ENGINEER BEFORE PROCEEDING WITH THE WORK.
G5
ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE CURRENT AUSTRALIAN STANDARDS CODES AND THE BY-LAWS AND ORDINANCES OF THE RELEVANT BUILDING AUTHORITY EXCEPT WHERE VARIED BY THE PROJECT SPECIFICATION.
G6
ALL DIMENSIONS SHOWN SHALL BE VERIFIED ON SITE. ENGINEER'S DRAWINGS MUST NOT BE SCALED.
G7
DURING CONSTRUCTION THE STRUCTURE SHALL BE MAINTAINED IN A STABLE CONDITION AND NO PART SHALL BE OVERSTRESSED.
G8
IMPORTANCE LEVEL = DOMESTIC
PROBABILITY FACTOR (Kp) = 1.0
THE STRUCTURE HAS BEEN DESIGNED FOR THE FOLLOWING EARTHQUAKE PARAMETERS:
G9
HAZARD FACTOR (Z) = 0.1
G2
G3
THESE DRAWINGS SHALL NOT BE USED FOR CONSTRUCTION UNTIL ISSUED AS "FOR CONSTRUCTION" BY THIS OFFICE. THE CONTRACTOR SHALL GIVE AT LEAST 1 WORKING DAY NOTICE FOR ALL ENGINEERING INSPECTIONS.
S01 -
GENERAL NOTES 1
S02 -
GENERAL NOTES 2
S03 -
TIMBER TRUSS - 600mm SPACING
S04 -
TIMBER TRUSS - 1200mm SPACING
S05 -
STEEL TRUSS - 600mm SPACING
S06 -
STEEL TRUSS - 1200mm SPACING
S07 -
CONVENTIONAL ROOF FRAMING
GENERIC AIR CONDITIONING ROOF MOUNT
STRUCTURAL DWG INDEX
TIMBER NOTES
ALL TIMBER WORK TO BE IN ACCORDANCE WITH AS 1720.1 AND 1684.2
T1
DURING CONSTRUCTION IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THE TIMBER IS PROTECTED FROM THE WEATHER AND TIMBER STRENGTH IS NOT IMPAIRED IN ANY WAY.
T2
ALL TIMBER AT JOINTS SHALL BE FREE OF DEFECTS.
T3
ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS1720 AND AS1684.
T4
ABOVE GROUND EXTERNAL HARDWOOD TIMBER AND SOFTWOOD TIMBER SHALL BE TREATED TO LEVEL "H3" IN ACCORDANCE WITH AS1604 U.N.O.
T5
CONCEALED SOFTWOOD TIMBER SHALL BE TREATED TO LEVEL "H2-F" IN ACCORDANCE WITH AS1604 FOR TERMITE PROTECTION.
T6
EXTERNAL TIMBER SHALL BE KILN DRIED TO ACHIEVE A MOISTURE CONTENT NOT EXCEEDING 15%.
T7
HARDWOOD TIMBER SHALL BE MINIMUM F11 STRESS GRAD U.N.O SOFTWOOD TIMBER SHALL BE MGP10 U.N.O.
T8
ALL CUT SURFACES OF TREATED MEMBERS SHALL BE RE-TREATED ON SITE TO ACHIEVE ORIGINAL HAZARD CLASS, IN ACCORDANCE WITH AS1604.
T9
TIMBER EXPOSED TO VIEW SHALL BE DRESSED (PLANED ALL ROUND).
T10
EXTERNAL TIMBER IN BUSH FIRE ZONES MUST BE SEASONED HARDWOOD AS DEFINED IN AS1720.2, WITH A MINIMUM DENSITY OF 650Kg/m AT12% MOISTURE CONTENT AND COMPLY WITH THE SOUTH AUSTRALIAN HOUSING CODE.
T11
THE USE OF CCA TREATED TIMBER IN A SCHOOL ENVIRONMENT MAY BE RESTRICTED BY SOUTH AUSTRALIAN GOVERNMENT OR OTHER OHS&W POLICIES. THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH THESE POLICIES.
T12
PROPRIETARY TIMBER CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS.
T13
ALL FASTENERS (SCREWS, BOLTS & BRACKETS) SHALL BE HOT DIPPED GALVANISED (NOT ZINC PLATED). FIXED IN ACCORDANCE WITH AS1720.1.
T14
BOLTED CONNECTIONS IN UNSEASONED TIMBER SHALL BE RE-TIGHTENED PRIOR TO THE FIXING OF CLADDING.
T15
ALL TIMBER SIZES, DETAILS, CONNECTIONS, TIE DOWNS AND BRACING SHALL BE IN ACCORDANCE WITH AS1684, NATIONAL TIMBER FRAMING CODE AND MANUFACTURER'S SPECIFICATIONS.
T16
THE BUILDING IS TO BE TERMITE TREATED TO THE REQUIREMENTS AND IN ACCORDANCE WITH AS3660 AND TO THE SPECIFICATIONS.
T17
DESIGN CRITERIA & KEY ASSUMPTIONS
EXISTING TRUSSES ARE ASSUMED TO BE AS PER TYPICAL LAYOUT SHOWN. OTHER SIZE TRUSSES ARE OUTSIDE OF THE SCOPE OF THIS GENERIC DESIGN.
D1
SPAN = 10.0m OR LESS. ANY SPANS OVER 10m ARE OUTSIDE GENERIC DESIGN BOUNDARIES AND A QUALIFIED ENGINEER SHOULD BE CONSULTED.
D2
PITCHES OF ROOF TO BE 15°, 22.5° AND 25°. ALTERNATE PITCHES BETWEEN 15° AND 25° ARE ADEQUATE. ANY PITCHES LESS THAN 15° OR GREATER THAN 25° ARE OUTSIDE GENERIC DESIGN BOUNDARIES AND A QUALIFIED ENGINEER SHOULD BE CONSULTED.
D3
IT IS RECOMMENDED THAT SEELEY INTERNATIONAL AIR CONDITIONING UNIT IS INSTALLED CLOSEST TO TRUSS TOP CHORD SUPPORTS AS POSSIBLE. I.E. ABOVE TRUSS DIAGONAL WEB.
D4
GENERIC SUPPORT FRAMES ARE DESIGNED FOR WIND CATEGORIES N1, N2 AND N3. REFER TO DETAILS FOR THE DIFFERENT WIND CATEGORIES. ANY WIND CATEGORIES OTHER THAN THE ABOVE ARE OUTSIDE GENERIC DESIGN BOUNDARIES AND A QUALIFIED ENGINEER SHOULD BE CONSULTED.
D5
EXISTING TRUSSES ARE ASSUMED TO BE IN GOOD CONDITION WITH NO SIGN OF DETERIORATION. PREFABRICATED TRUSSES EARLIER THAN 1997 WILL REQUIRE CONFIRMATION OF SUITABILITY IN ACCORDANCE WITH REGULATION 74 OF THE DEVELOPMENT REGULATION 2008.
D6
ADDITIONAL DEFLECTION OF TRUSSES SHOULD BE EXPECTED, HOWEVER THIS MAY BE MINIMAL AND ACCEPTABLE.
D7
TRUSS SPACING @ 600 CTRS IS ASSUMED TO SUPPORT A TILE ROOF. TRUSS SPACING @ 1200 CTRS IS ASSUMED TO SUPPORT A SHEET ROOF
D8
CUTTING OF ANY TRUSS MEMBERS IS NOT ALLOWED
D9
IF ANY DOUBT IN THE INSTALLATION OF DESIGN, PLEASE LIAISE WITH ENGINEER
D10
ALL TYPE 17 SCREWS TO BE 12g 'BUGLE' SCREWS OR SIMILAR APPROVED (U.N.O.) LENGTH TO SUIT.
T18
ISSUED FOR CERTIFICATION
C6
HN
28.2.19
IF TRUSS LENGTH EXCEEDS 10m BUT HAS SUPPORTS REDUCING THE SPAN TO 10m OR LESS, GENERIC DESIGN IS STILL APPLICABLE.
D11
ISSUED FOR CERTIFICATION
C7
HN
28.3.19
FROM MLEI ANALYSIS TIMBER TRUSSES SPACED AT 1200 CTS IN N3 WIND ZONE REQUIRE 90x35 MGP12 TOP CHORDS.
D12
ISSUED FOR CERTIFICATION
C8
TN
05.04.19
APPENDIX – A GENERIC STRUCTURALLY
ENGINEERED ROOF MOUNTING SCHEMES: