CW-6S INDIRECT COOLER INSTALLATION MANUAL | 43
APPENDIX – B ‘PIECE BY PIECE’ INSTALLATION
31. Loosely constrain the cables in the plenum area to the
cable tie mount on the plenum.
Important! Do not
overtighten. Do not choke the pressure sensor hoses.
32. Adjust the cable routing runs and neaten up the cable runs
in the tank. Re-fit cable ties to constrain the cables such
that they are suspended above the water.
33. Refit the electronics cable cover and screw to the plenum.
Refer to “Removing the Top Motor/Fan Assembly:” on page
38
34. Transport all 8 manifold assemblies to the roof and fit to
the cooler. To do this, carefully slide the manifolds into the
plenum outer ensuring a tight fit with no gaps between
the interfacing surfaces. All manifold assemblies should
mate firmly with the plenum outer to form a good sealing
face. Handle the manifolds with care. Excessive force may
damage the foam and/or manifold assembly.
ILL3127-A
35. Secure the manifold assemblies by pulling and locking
the lower and upper manifold retention straps into the
dedicated slots on the manifolds.
ILL2814-A
36. Reconnect the vertical hose pillars to the hose restraint
clips on the foam plenums.
ILL2815-A
APPENDICES
30. Reinstall all 8 manifold retention straps onto the top motor/
fan assembly. Slide the ring end over the spigot. Stretch the
strap so that the head of the strap pulls back against the
manifold to retain it.
29. Route the top motor cables down to the electronics
enclosure via the cable restraint built into the foam plenum
that is closest to the drain valve (i.e. the right hand
side foam plenum when facing the front of the cooler).
Reconnect the cables according to the corresponding
labels. Refer to the wiring diagram shown in Step 5,
“Removing the Top Motor/Fan Assembly:” on page 38.
ILL3127-A