CW-6S INDIRECT COOLER INSTALLATION MANUAL | 21
MAINS AND COMMUNICATION CABLE PATH
This step leads on from the ‘Preliminary Cable Installation’
section, refer to “PRELIMINARY CABLE INSTALLATION” on
page 15. The power socket end of the mains cable should be
passing through the corner recess slot in the dropper transition
and hanging loose on the INSIDE of the dropper.
Ensure it is
not being pinched or crushed.
1. The communications cable should be hanging loose on the
outside of the dropper.
MAINS CABLE CONNECTION
ILL3029-B
2. Feed the control cable through the rear access hole (RHS)
from the underside of the tank.
3. The control cable needs to be routed though the cable tray
on the inner wall of the tank, and then fed through to the
control module.
Important! Ensure the mains cable is not submerged
or touching the water in the tank at any point along
the cable length. Make use of the resealable cable
restraints. Cable tie to existing looms if necessary.
4. Remove the Control Module cover. Connect the
communications cable to the socket labelled “Wall Control”
Replace the cover.
5. Clip the loose cables into the restraint on the rear tank hole
to lock them into place and then insert the plug provided
from inside the tank.
This will seal the hole in the tank.
6. Push the remainder of the loose cables back down into
the dropper. Leave some slack on the cables so they sit
comfortably.
ILL3109-A
ILL3110-A
ILL3111-B
UNDERSIDE VIEW
TOP VIEW
ILL3112-A
UNDERSIDE VIEW
WALL CONTROL
COMMUNICATION
CABLE
ISOLATION
SWITCH
ILL3111-C
ILL3111-C