Flash Codes
Appendix
The Sealite SL-C510 may be set to any of 256 IALA recommended flash settings which are user
adjustable onsite without the need for external devices.
SEALITE
®
code reference is listed by number of flashes
For the latest version of this document visit
or email
Symbols
FL
Flash followed by number Eg. FL 1 S, one flash every second
F Fixed
Q
Quick Flash
VQ
Very Quick Flash
OC
Occulting; greater period on than off
ISO
Isophase; equal period on and off
LFL
Long Flash Long
MO
Morse code ( ) contains letter
For example, VQ (6) + LFL 10 S means 6 very quick flashes followed by a long flash, during a 10-second
interval.
The amount of power your lantern draws through the night depends on the duty cycle, i.e. the amount
of time on as a proportion to the timing cycle. For example, 0.5 seconds on and 4.5 seconds off equals a
10% duty cycle.
It is best to operate at the lowest duty cycle appropriate to the actual needs of the application.