Prompting Messages and Troubleshooting
A) Prompting Messages:
■
Trig level at limit! :
Mention you that the trigger Level is at a limit when you turn the Trig level knob.
■
Horizon position at limit! :
Mention you that the horizontal position is at a limit when you turn the
horizon position knob.
■
Volts/Div at limit! :
Mention you that the vertical voltage have already touched the Min 2
m
V/div or the
Max 10V/div.
■
Volts position at limit! :
The system would display this information when the vertical position is at a
limit.
■
Sec/Div at limit! :
Prompts that the Volts/Div is at full range while turning the vertical scale knob.
■
Holdoff time at limit! :
Turn the “Universal” knob when holdoff time has been to max or min value, now
the system will clew this information.
■
Functions isn’t useable! :
Under several special modes, the some functions could not be running.
■
No signal! :
The system would clew this information when the signal could not match the auto set
condition. (Using in the auto set)
■
Adjust at limit! :
You could adjust the pulse width by the universal knob till the pulse width has reached
min20.0ns or max 10.0s.
■
Location Empty! :
If you have no stored waveforms or setups on some location, the screen will display
this information when you press the “Recall” button on this location.
■
USB Flash Drive Plug In! :
This information will appear when you invert the USB Flash Drive to the
USB Host port.
■
USB Flash Drive Pull Out! :
This information will appear when you pull out the USB Flash Drive.
■
Store Data Success! :
Save setup data, waveform data or picture data to the internal of the
oscilloscope or USB flash successful.
■
Ready Data Success! :
Read setup data or waveform data from the
internal of the oscilloscope or
USB flash successful.
■
Please set Back USB to printer! :
Press the “S/div” knob will appear this information on the screen
when the “Print Key” option is set to “Print Picture” and the “Back USB” option is set to “USBTMC”.
■
USB Flash Drive isn’t connected! :
When the “Save To” option is set to “File” or the “Print Key” option
is set to “Save Picture” in “Save/Recall” menu , Press the “Save” option button or the “S/div” knob before
inverting the USB Flash Drive to the USB Host port will appear this information on the screen.
■
Record Wave Success! :
This message will appear when you finish recording waveforms.
B) Troubleshooting
1. After the oscilloscope is powered on the screen remains dark, please do steps as follows
■
Check the power cable’s connection.
■
Ensure the power switch is turned on.
User Manual SMO702, SMO1002
Summary of Contents for SMO1002
Page 1: ...Digital Oscilloscopes SMO702 SMO1002 User Manual ...
Page 59: ...59 Fig 45 B Cursor Measurement Auto Mode User Manual SMO702 SMO1002 ...
Page 62: ...62 Table 40 All Measurement function menu User Manual SMO702 SMO1002 ...
Page 63: ...63 Table 41 Introduction of the Measure Type User Manual SMO702 SMO1002 ...
Page 91: ...91 User Manual SMO702 SMO1002 ...
Page 92: ...92 User Manual SMO702 SMO1002 ...
Page 93: ...93 User Manual SMO702 SMO1002 ...
Page 98: ...98 Default Setting User Manual SMO702 SMO1002 ...
Page 99: ...99 User Manual SMO702 SMO1002 ...