F-2
Possible Output Configurations
707-161 Rev. 3
Possible Output Configurations
(continued)
2. Change the mode to PSI.
You may see stream types such as PAT, CAT, NIT, SDT, TDT, EMM, and so
on, depending upon the uplink setting. Move the pointer up and down to
different streams. Make sure the PAT (PID 0) is routed to the transport
outputs. Use the
▲
,
▼
, and SELECT keys to point to the appropriate PID.
Use the MAP key to modify the output routing. The other PSI PIDs do not
need to be routed to the outputs.
continued on next page