Mounting and adjustments, size 10 - 14
6.4.2 Mounting magnetic switch MMS 22 / reed switch RMS 22
CAUTION
Risk of damage to the sensor during assembly!
•
Observe the maximal tightening torque.
The sensors can be mounted via four grooves in the housing of the
product.
1. Connect sensor and secure cable, see the Sensor Assembly and
Operating Manual.
2. Apply air pressure to connection "A" (4).
✓
Pinion (2) swivels towards the end position.
3. Insert or screw the first sensor (1) into the groove (5).
4. Move the sensor along the groove until it actuates.
5. Tighten set screw (8).
✓
Tightening torque: 10 Ncm
6. Bleed connection "A" (4).
7. Actuate connection "B" (3).
✓
Pinion (2) swivels into the other end position.
8. Insert or screw the second sensor (1) into the groove (6).
9. Move the sensor along the groove until it actuates.
10. Tighten set screw (8).
✓
Tightening torque: 10 Ncm
11. Check the switching position and test its function.