Maintenance, size 16 - 40
122
12.00 | SRM | Assembly and Operating Manual | en | 1346850
14. Loosen screw (6).
✓
Electrical rotary feed-through (EDF) is dismantled.
15. Change all seals.
16. Disassemble base unit and replace seals,
17. If necessary, disassemble the fluid feed-through (MDF) and
.
Assembling
1. Assemble product in the reverse order. Observe the following
when doing this:
✓
Unless otherwise specified, secure all screws and nuts with
Loctite no. 243 and tighten with the appropriate tightening
torque.
2. When installing the strain relief, feed through half of the wires
per gap. Carefully retighten each wire so that they are slightly
tensioned in the base unit.
IMPORTANT! Do not pull on the
cable connectors!
3. Mount product onto the system/machine.