Technical data
3.2 Basic data, size 16 - 40
Designation
Value
Pressure medium
Compressed air, compressed
air quality according to
ISO 8573-1:7 4 4
Nominal operating pressure [bar]
6
Min. pressure [bar]
4
Max. pressure [bar]
6.5 / 8 (MDF)
Connection data for variant with electrical rotary feed-through "EDF"
Designation
Value
Max. Voltage [V]
48
Max. Current per wire [A]
1
More technical data is included in the catalog data sheet.
Whichever is the latest version.
The catalog data sheet contains diagrams for designing the
maximum permissible mass moment of inertia.
The SCHUNK contact person provides support for designing further
applications.
Ambient conditions and operating conditions
Designation
Value
Ambient temperature [°C]
Min.
Max.
+5
+60
Protection class IP
65
Noise emission [dB(A)]
≤ 70
Ambient conditions and operating conditions for variant with electrical rotary feed-
through (EDF)
Designation
Value
EDF 48 V / 1 A
EDF 48 V /
750 mA
Ambient temperature [°C]
Min.
Max.
+5
+50
+50
+60
Protection class IP
65
Noise emission [dB(A)]
≤ 70
23