Assembly and settings, size 16 - 40
72
12.00 | SRM | Assembly and Operating Manual | en | 1346850
7.2.3.2 Size 20 - 40
Connections on the EDF
1
Fluid connection - Input
2
Fluid connection - Output
Hose-free direct connection
Hose-free direct connection
3
Product
4 *
O-ring
5
Attachment
* Contained in accessory pack.
NOTE
• On the fluid feed-through, associated inlets and outlets are
marked with numbers.
• If two channels are pressurized simultaneously: Use channels
1 + 2 or 3 + 4.
Dimensions
Item Designation
SRM
20
25
32
40
1
Fluid connection
Input
M 5
M 5
M 5 G 1/8"
4
O-ring [mm] (Output - Hose-
free direct connection)
Ø3 x 1 Ø3 x 1 Ø5 x 1 Ø5 x 1
Summary of Contents for SRM 10