6.
Only for variant "SI":
Mount switching cam (6) with set-screw.
✓
Tightening torque: 0.5 Nm
7. Check the switching positions and test the function, re-adjust
the position if necessary.
7.4.4.1 Installing the "inductive monitoring" mounting kit
1. Insert four centering sleeves (1) into the pinion (2) and
housing (3).
2. Fasten the base plate (4) to the housing (3) with four
screws (5).
3.
Only for variant "SI"
: Mount control cam (6) to adapter disk (8)
with set-screw (7).
4. Fasten adapter disk (8) to pinion (2) with screws (9).
5. Install two centering pins (10) and one screw (11) in each
sensor holder (12).
6. Mount sensor holder (12) to base plate (4) with screw (13).
7. Mount the sensor,
.