![SCHUNK SRM 10 Assembly And Operating Manual Download Page 90](http://html.mh-extra.com/html/schunk/srm-10/srm-10_assembly-and-operating-manual_1216055090.webp)
Assembly and settings, size 16 - 40
90
12.00 | SRM | Assembly and Operating Manual | en | 1346850
7.4.4 Mounting inductive proximity switch IN 80
NOTE
The sensor can only be used with the variants "SI" or "SF".
CAUTION
Risk of damage to the sensor during assembly!
•
Observe the maximal tightening torque.
With the sensors, three positions can be queried:
• End position "A"
• Center position "M"
• End position "B"
The following assembly steps are the same for all three positions:
Version 1: Sensor bracket (1) with sleeve (4)
NOTE
The switching cams (6) have been factory set at 0°, 90° and 180°.
With the variant "SI", the switching cams can be adjusted.
1. Pull all sleeves (4) out of the brackets (1) until the stop to
prevent a collision with the switching cam (6) and sleeve (4)
when swiveling.
2. Connect sensor and secure cable, see Sensor Assembly and
Operating Manual.
3. Push the sensor (3) into the sleeve (4) until the stop.
4. Tighten set-screw (2).
✓
Tightening torque: 40 Ncm
5.
Only for variant "SI":
Turn the product counter-clockwise to
the desired position.
Summary of Contents for SRM 10