SERCOS Module XP-SRC
128
Operating Manual XCx 300 / 500 / 540 Version 09/08
Establishing Communication via the SERCOS Ring
Communication on the SERCOS ring is established in 5 phases
(phases 0..4).
Establishment of communication is always restarted when
the controller is switched on
the reset button (on the XCN) is operated,
the drive parameters are changed, or
an error (e.g. cable break) is found on the SERCOS ring.
Several seconds may pass before communication phase 4 is
achieved. You can follow the establishment of communication using
the LED displays.