Entering the reference percentage value
The reference weight for 100% is entered using the keypad and the
O
key is
pressed to initialize the application.
Reading the reference percentage value
The reference weight can be read using a barcode scanner.
h
The entered value remains active until deleted by pressing the
c
key or until
overwritten by a new value. It remains saved after the scale is switched off.
Preparation
t
Open the
APPLIC. / APPLIC.1 / PERCENT
menu
Available parameter settings
* = Factory setting
MIN.INIT
Minimum load for initialization
3.6
1 digit
1 digit*
3.6.1
2 digit
2 digits
3.6.2
5 digit
5 digits
3.6.3
10 digT.
10 digits
3.6.4
20 digT.
20 digits
3.6.5
50 digT.
50 digits
3.6.6
100 diG.
100 digits
3.6.7
200 diG.
200 digits
3.6.8
500 diG.
500 digits
3.6.9
1000 dI.
1000 digits
3.6.10
RESOLUT
Resolution for calculation of reference value
3.9.
DISP.ACC
Display accuracy
3.9.1*
10 FOLD
Display ac 1 decimal place
3.9.2
100FOLD
Display ac 2 decimal places
3.9.3
DEC.PLCS
Decimal places in displayed result
3.10
NONE
None
3.10.1*
1 DEC.PL
1 decimal place
3.10.2
2 DEC.PL
2 decimal places
3.10.3
3 DEC.PL
3 decimal places
3.10.4
SAVE WT.
Parameter for saving weight values
3.11
STABIL.
With stability
3.11.1*
ACC.STAB
With increased stability
3.11.2
REF.WP
Reference weighing instrument
3.13.
NO WP
No weighing platform selected
3.13.1*
wp 1
Weighing platform WP1
3.13.2
wp 2
Weighing platform WP2
3.13.3
CALC.DIS
Display of calculated value
3.15.
RESID.QT
Residual quantity
3.15.1*
LOSS
Loss
3.15.2
)
t
To save the setting, press the
)
key.
( (
...
t
To exit setup: Press the
(
key several times.
Minimum load for initialization
You can set the minimum load here, i.e. the load that must be placed on the
weighing platform in order to carry out the application. If the load on the platform
is too light, the following will occur:
– Error code
Inf 29
appears,
– The weighing platform is not initialized,
– The preset reference sample quantity is saved.
68
Operating Instructions Combics Indicators
Operation
Summary of Contents for CAIS1
Page 127: ...Operating Instructions Combics Indicators 127 Declarations of Conformity...
Page 128: ...128 Operating Instructions Combics Indicators Declarations of Conformity...
Page 129: ...Operating Instructions Combics Indicators 129 Declarations of Conformity...
Page 130: ...130 Operating Instructions Combics Indicators Test Certificate...
Page 131: ...Operating Instructions Combics Indicators 131 Plates and Markings...
Page 132: ...132 Operating Instructions Combics Indicators Plates and Markings...
Page 133: ...Operating Instructions Combics Indicators 133 Plates and Markings...
Page 134: ...134 Operating Instructions Combics Indicators Plates and Markings...
Page 155: ...Operating Instructions Combics Indicators 155 Appendix Guide to verification...
Page 158: ...158 Operating Instructions Combics Indicators...
Page 159: ...Operating Instructions Combics Indicators 159...