UPS Characteristics
41
§
§
1
1
2
2
.
.
3
3
P
P
r
r
o
o
t
t
e
e
c
c
t
t
i
i
v
v
e
e
F
F
u
u
n
n
c
c
t
t
i
i
o
o
n
n
T
T
a
a
b
b
l
l
e
e
The following table shows the functions and operations to protect the UPS.
Indicators/Indications of LCD Panel and UPS Unit
Control Panel
Transfer Signal and Contact Signal Output
Item
Green
INPUT
Green
OUTPUT
Green
BACKUP
Red
WARNING
Red
ALARM
LCD
Indications
*1
Alarm
Buzzer
*2
AC
Input
Error
Battery
Voltage
Drop
AC
Output
Inverter
Output
Bypass
Output
Device
Error
Protective
Functions
(UPS
Operations)
Notes
Preparation
- - - -
-STANDBY-
******
- - - - - - -
Rectifier and
charger operation
Receiving
power
Normal
- - -
-ONLINE-
******
- - -
- -
Inverter operation Receiving
power
Normally
Operating
Unit
-
-
-SYS FAILURE-
*****
①
- -
-
Inverter operation
Se
ri
ou
s
m
alf
unc
ti
on
Malfuncti
oning
Unit
-
-
-SYS FAILURE-
*****
①
- -
-
Inverter shutdown
*3
Overload
- - -
-BYPASS-
******
④
- -
-
-
-
Forced bypass
- - -
-BYPASS-
******
-
- -
-
-
Bypass power
supply
Manual switch
to bypass
operation
High input
voltage
- -
-BATTERY-
******
②
-
- -
High input
voltage
(Prolonged,
battery voltage
drop)
- -
-BATTERY-
******
③
- -
Power outage
- -
-BATTERY-
******
②
-
- -
Power outage
(Prolonged,
battery voltage
drop)
- -
-BATTERY-
******
③
- -
Input error
(Frequency)
- -
-BATTERY-
******
②
-
- -
Input error
(Prolonged,
battery voltage
drop)
- -
-BATTERY-
******
③
- -
Stop rectifier and
charger
Continue inverter
operation
Battery
operation
Complete
Battery
Discharge
-
-BYPASS-
******
①
-
-
-
Inverter shutdown
Bypass power
supply
-
Battery voltage
error
- - -
-******-
Batt Vol Error
⑥
- -
-
Batteries not
connected
Battery
Remaining
Service Life
Warning
- - -
-******-
Batt Life Warn
⑤
- -
- -
-
Battery life
- - -
-******-
Batt Life End
⑤
- -
- -
Inverter operation
-
*1. The "******" indication on the LCD indicates the UPS status, etc.
*2. Buzzer sound patterns:
①
* Continuous tone
②
**
・・・・・・
**
・・・・・・
③
********
・・・・・・
Continuous tone
④
****
・・・・・・
****
・・・・・・
⑤
*****
・・・・・・
*****
・・・・・
⑥
*******
・・・・・・
*******
・・・・・
See “§10. When A Buzzer Sounds” and perform the corresponding countermeasure.
If the UPS has malfunctioned, contact your sales representative or SANYO DENKI.
*3. In the following cases, the UPS switches to bypass operation when a serious failure occurs.
When only one UPS Unit is connected.
When all UPS Units have malfunctioned.
When a malfunction occurs and operation with a normally operating UPS Unit will result in an operation overload state.
Lit LED:
Blinking LED:
Buzzar alarms:
①
to
⑥
Sending of transmission signal:
○
Indication of the marks in the table as follows.
Press
to stop the buzzer.
Tip