− 118 −
Error code
Description of error
How to recover
E496
Condensation at sewing end length over
When condensation pitch X number of stitches exceeds 15.0 mm
Possible to re-
start after reset.
E497
Back tack at sewing end length over
When back tack pitch X number of stitches exceeds 6.0 mm
Possible to re-
start after reset.
E498
Condensation at sewing start length over
When condensation pitch X number of stitches exceeds 15.0 mm
Possible to re-
start after reset.
E499
Back tack at sewing end length over
When back tack pitch X number of stitches exceeds 6.0 mm
Possible to re-
start after reset.
E702
CPU runaway detection
When program abnormality has occurred in CPU
Turn OFF the
power.
E703
Panel is connected to the sewing machine which is not sup
-
posed (Machine type error)
When the machine type between panel and sewing machine is
different in the initial communication
Possible to re-
start after reset.
E704
Inconsistency of system version
When system software version is inconsistent in the initial com-
munication
Turn OFF the
power.
E730
Main shaft motor is defective or lacking for phases.
When encoder of sewing machine motor is abnormal
Turn OFF the
power.
E731
Main motor hole sensor is defective or position sensor is
defective.
When hole sensor of sewing machine motor or position sensor is
defective
Turn OFF the
power.
E733
Reverse rotation of main shaft motor
When the sewing machine motor rotates in the reverse direction
Turn OFF the
power.
E802
Power momentary cut detection
When input power is momentarily cut
Turn OFF the
power.