− 53 −
No.
Item
Setting range
/
Edit unit
Initial value
Flap concealed stitching data (Right sewing end)
Position of sewing end of right-hand flap is adjusted.
* It is possible to set only when
is set to flap sewing.
–9.9 to 9.9
/
0.1mm
0.0mm
※
Center knife actuating position setting
Cutting position of center knife at sewing start/sewing end is set.
* Be sure to adjust with every gauge so that the position meets the top of
letter V of corner knife.
0.0 to 25.0
/
0.1mm
* APW-895L
only
Max. 30.0
7.0mm
Sewing start center knife
position
Sewing end center knife
position
Corner knife actuating position at sewing start
Cutting position of corner knife at sewing start is set.
–9.9 to 9.9
/
0.1mm
0.0mm
Corner knife actuating position at sewing end
Cutting position of corner knife at sewing end is set.
–9.9 to 9.9
/
0.1mm
0.0mm
Marking light setting
Marking light irradiation position in each case of sewing start irradiation/
sewing end irradiation/center irradiation is set. When set value 0.0n mm,
the sewing position is the same as the marking light irradiation position.
Use this function when irradiating the marking light to the position that is
different from the sewing position.
–100.0 to
100.0
* Sewing
start irradia
-
tion :
–80.0 to
100.0
/
0.1mm
0.0mm
Sewing start irradiation
Sewing end irradiation
Center irradiation
Roller stacker stop/motion change-over
Stop/motion of roller stacker is selected.
* It is displayed only when
is set to roller stacker mounting.
- - -
※
Stop
Motion
Clamp bar stacker stop/motion change-over
Stop/motion of clamp bar stacker is selected.
* It is displayed only when
is set to clamp bar stacker mounting.
- - -
※
Stop
Motion
※
. . . Item that is not displayed due to other setting state