− 59 −
No.
Item
Setting range
/
Edit unit
Initial value
Flap length
Length of flap is set.
It is possible to set only when
automatic interlining supplying de-
vice is selected to motion and
sewing mode changeover is select
-
ed to flap sewing.
* This setting is set to determine the interlining feeding length of automatic
interlining supplying device. Sewing length is determined by the detection
of flap sensor.
37.0 to
220.0
/
0.1mm
150.0mm
※
Sewing speed under the high-speed mode
Number of revolutions at lockstitch section is set.
* It is possible to set only when
sewing speed setting selection is
set to pattern data selection.
1000 to
3000
/
100sti/min
2500sti/min
※
Sewing speed under the low-speed mode
Number of revolutions at condensation and back tack sewing sections is set.
* It is limited by
sewing speed under the high-speed mode.
* It is possible to set only when
sewing speed setting selection is
set to the selection of pattern data.
* In case of back tack sewing, the upper limit of number of revolutions of
the actual low speed is limited to 1,500 sti/min.
1000 to
2500
/
100sti/min
1500sti/min
※
※
. . . Item that is not displayed due to other setting state