− 26 −
(3) Basic operation
①
Turn ON the power switch.
First, turn ON the power switch.
Reset pop-up screen is displayed after displaying WELCOME
screen. Press RESET button
A
.
Next, language selection pop-up screen is displayed. After select-
ing the language you desire to display, press ENTER button
B
. Then the independent sewing input screen (screen A) of the
figure below is displayed.
B
A
When RESET button is pressed, the binder goes up. So,
be careful.
Buttons that perform common operation in the respective screens of IP-420 are as described below.
(2) Buttons used in common
Pictograph
Name
Description
CANCEL button
Pop-up screen is closed. In case of the data change screen, the data during
changing can be cancelled.
ENTER button
Data changed are determined.
UP SCROLL button
This button scrolls button or display upward.
DOWN SCROLL button
This button scrolls button or display downward.
RESET button
This button releases error and the like.
NUMBER INPUT button
Ten keys are displayed and input of number can be performed.
CHARACTER INPUT button
Character input screen is displayed.
When ending the selection screen with CANCEL button
or ENTER button
without performing the lan
-
guage selection, the language selection screen is dis
-
played whenever the power is turned ON.