background image

 
 

 
 

 

17 Gallon Box Extractor O

WNER

M

ANUAL 

 

&

 

P

ARTS 

L

IST

 

This equipment is intended for commercial use only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRUSTED CLEAN MODEL

      

TPL-17-150-CE-HEAT-TCP

 

 

1-888-722-5508 

Summary of Contents for TPL-17-150-CE-HEAT-TCP

Page 1: ...17 Gallon Box Extractor OWNER S MANUAL PARTS LIST This equipment is intended for commercial use only TRUSTED CLEAN MODEL TPL 17 150 CE HEAT TCP 1 888 722 5508 ...

Page 2: ...it may damage the solution system To prevent seal damage and chemical build up to the pump system run clean water through the solution lines after each day s use Use only commercially available carpet cleaning solutions and defoamer intended for use with machines of this type Do not use dyes bleaches ammonia or other additives The use of powdered cleaning solution if not diluted properly may resul...

Page 3: ...ups must be in place and water flowing through the heater prior to turning heater on Failure to do so may cause internal component damage and will void the warranty For more information see Warnings section 3 Spray water through the tool wand before turning on the heater to assure that there is water flow 4 Heater must be filled with water or water based solutions at all times when in use 5 Plug h...

Page 4: ...iled areas like arm rests pre treat with a recommended pre spray solution DAILY MAINTENANCE 1 Always keep the machine clean inside and out 2 Pour 1 gallon of clean hot water into the solution tank Turn on and flush the entire system through the wand nozzles for about a minute to prevent mineral or chemical build up A periodic use of a 1 3 white vinegar and water solution helps to break down build ...

Page 5: ... build up on wand head 4 Defective vacuum hose 5 Loose connection in the vacuum motor s SOLUTION SYSTEM Pump motor on no spray through spray tips 1 Clogged spray tips 2 Clogged solution intake filter screen 3 Plugged female quick disconnect coupler or couplers not fully engaged 4 Punctured pump diaphragm 5 Defective or clogged check valve 6 Crack in pump housing 7 Lost prime Uneven or weak spray f...

Page 6: ...12 13 15 16 27 26 25 24 22 20 21 22 28 34 37 38 55 39 40 45 46 47 46 48 49 50 7 51 52 54 56 57 58 59 62 54 6 17 7 63 64 65 66 32 33 42 41 7 15 31 60 61 23 53 17 GALLON BASE 2 3 08 36 1 14 19 18 29 43 44 55 6 35 30 5 10 ...

Page 7: ...ECK VALVE BODY 1 31 C02291 HEATER PLATE HEX 4 32 D010379 HEATER MOUNTING PLATE 1 33 K10691 PVC PIPE 25IN 4 34 A00061 3 8 BARB X 1 4RP BRASS 1 35 H02564 2 LABEL CAUTION MOTOR HOUSING 1 36 C11165 SCREW 8 X 1 IN PAN BLACK 4 37 F11790 1STCB HEATER TUNNEL COVER BLUE GRANITE 1 38 B11779 STUB 12 3 SJTW YELLOW 1 39 C00293 8 X 5 IN PAN BLACK SMS PHILLIPS 2 40 B00192 MOUNT NYLON TIE 1 41 B11606 STRAIN RELIE...

Page 8: ...4 3 6 7 8 9 10 11 1 2 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 17 GALLON Upper 3 25 08 5B 5D 5A 5 5C 53 ...

Page 9: ...4 SWITCHPLATE 1 23 E010453 GASKET SWITCH BRACKET 1 24 B00177 1 TERMINAL LUG FEMALE QD 25 X 032 4 25 B00185 30 WIRE 14 GA WHITE UL1015 5IN 1 26 C02315 LOCKWASHER 10 INT STR SS 2 27 C00264 NUT 10 31 1 28 C00288 1 25 20 X 2 25 FLAT HEAD 4 29 C00288 25 20 X 1 5 FLAT HEAD 4 30 K00666 90 ELBOW SCH D 40 1 5 IN 1 31 K00665 1 HOSE ADAPTER 1 5 IN BLACK 1 32 C00313 HEX BOLT 25 X 20 X 75 2 33 C02312 LOCKWASHE...

Page 10: ...NOTES Revised 01 31 13 ...