P-7
Part #1167879 08/2008
Test Mode
Vend Specific Column:
1. Still in Test Mode, Press Button 2 to scroll until “Vend Specific Column” is displayed.
2. Press Button 4 to Enter.
3. Close outer door.
4. Display will read ‘Test Vend Column No. #XX’.
5. Press 2/3 to choose the column number, Press 4 to vend, Press 1 to Exit.
The vendor will revert back to sales mode if it is idle for 5 minutes.
Test Mode
Test Hopper Flap:
1. Still in Test Mode, Press Button 2 to scroll until “Test Hopper Flap” is displayed.
2. Push Button 4 to Enter. – Testing in Progress –
3. Exit on Button 1.
Test Mode
Test Hopper Bucket:
1. Still in Test Mode, Press Button 2 to scroll until “Test Hopper Bucket” is displayed.
2. Push Button 4 to Enter. – Testing in Progress –
3. Exit on Button 1.
Test Mode
Test Vend Detection:
1. Still in Test Mode, Press Button 2 to scroll until “Test Vend Detection” is displayed
2. Push Button 4 to Enter – Display will read ‘Testing in Progress’ followed by:
STANDARD FONT DISPLAY
●●●
– there is nothing blocking the optics, or
○○○ –
optics are blocked.
EUROPEAN FONT DISPLAY
∑ ∑ ∑
– there is nothing blocking the optics, or
σ σ σ –
optics are blocked.
Hopper Bucket will open to allow blocking/ unblocking of the optics.
3. Exit on Button 1.
Test Mode
Test Motors:
After completion of work in Test Motors, please ensure that X, Y, Z and Clamp Motors have
returned to the ‘Home’ position before closing the outer door.
1. Press Button 2 to scroll until “Test Motors” is displayed.
2. Press Button 4 to Enter.
Test Motors
X Motor:
1. Still in Test Motors, Press Button 2 to scroll until “X Motor” is displayed.
2. Enter on Button 4 – ‘Pls wait….Entering Test Motors Mode’, followed by ‘Test
Motors X Motor’ – Rail should move to the top of the vendor.
3. Enter on Button 4 – X Motor Go Home.
Summary of Contents for Vendo Vue SXY 30
Page 1: ...i Part 1167879 07 2008 SXY TABLE OF CONTENTS...
Page 4: ...S 1 Part 1167879 07 2008 SXY SAFETY SECTION...
Page 7: ...S 4 Part 1167879 07 2008 FIGURE 1...
Page 12: ...S 9 Part 1167879 07 2008 FIGURE 3 0 8 AMP FUSE 3 15 AMP FUSE...
Page 20: ...S 17 Part 1167879 07 2008 NOTES...
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 29: ...CL 1 Part 1167879 07 2008 SXY CLEANING INFORMATION SECTION...
Page 32: ...CL 4 Part 1167879 07 2008 NOTES...
Page 33: ...P 1 Part 1167879 08 2008 SXY VEC 15 4 PROGRAMMING SECTION...
Page 47: ...P 15 Part 1167879 08 2008 SXY40 Space to Sales Plan o gram SXY30 Space to Sales Plan o gram...
Page 48: ...P 16 Part 1167879 08 2008 SXY40 Space to Sales Plan o gram SXY30 Space to Sales Plan o gram...
Page 63: ...P 31 Part 1167879 08 2008 WIRING DIAGRAM...
Page 64: ...P 32 Part 1167879 08 2008 WIRING DIAGRAM CONT...
Page 65: ...P 33 Part 1167879 08 2008 CUSTOM SPACE TO SALES DIAGRAM...
Page 73: ...ST 1 Part 1167879 07 2008 SXY SHELVES TRAYS PARTS SECTION...
Page 75: ...ST 3 Part 1167879 07 2008 6 12 14 16 7 3 13 15 11 5 5 4 10 8 19 2 9 17 17 19 18...
Page 77: ...ST 5 Part 1167879 07 2008 NOTES...
Page 106: ...M 1 Part 1167879 07 2008 SXY MAINTENANCE SECTION...
Page 114: ...M 9 Part 1167879 07 2008 NOTES...
Page 115: ...T 1 Part 1167879 07 2008 SXY TROUBLESHOOTING SECTION...
Page 128: ...T 14 Part 1167879 07 2008 NOTES...