T-13
Part #1167879 07/2008
Compressor runs but cabinet temperature
warm.
Loss
of
refrigerant
Replace the refrigeration unit.
Smashed tubings
Replace the refrigeration unit.
Defective drainage
Make sure the drain hose is not kinked or clogged.
Defective temperature sensor
Replace the temperature sensor
.
Poor
air
flow
Make sure nothing is sitting in front of the evaporator
.
Defective control board
Replace the control board.
Defective door seal
Make
sure
the
vend
flap
and
gasket
are
not
open.
Defective heat exchange on condenser/ Blocking air
flow
by
dust,
lint
or
fins
damage
Clean
the
surface
of
the
condenser
fins
or
straighten
the
bent
fins.
Both compressor and condenser fan motors
will not operate.
Bad refrigeration control relay
.
T
est relay using relay test function of the electronic controller
. Replace
relay if necessary
.
Bad connection at power board.
Check wiring connections. Make corrections if necessary
.
Evaporator frosted over
.
Loss
of
refrigerant
Replace the refrigeration unit.
Smashed tubings
Replace the refer unit.
Defective drainage
Make sure the drain hose is not kinked or clogged. Re-install hose
correctly if kinked or clogged.
Defective temperature sensor
Replace the temperature sensor
.
Defective control board
Replace the board.
Poor sealing
Check
gasket,
vend
flap,
and
permagum
on
the
bulkhead.
Product freezing up (too cold).
T
emperature setting too low
.
Adjust set point in control board.
Defective temperature sensor
Replace the temperature sensor
.
Defective control board
Replace the control board.
Excessive noise.
Fan blade hitting shroud or transformation or loose
fitting
Replace the fan blade or re-install correctly
.
From
the
inside
of
fan
motor
or
loose
fitting
Re-install or replace the motor
.
From
the
inside
of
compressor
or
loose
fitting
Replace the refrigeration unit.
ERROR
PROBABLE
CAUSE
CORRECTIVE
ACTION
Summary of Contents for Vendo Vue SXY 30
Page 1: ...i Part 1167879 07 2008 SXY TABLE OF CONTENTS...
Page 4: ...S 1 Part 1167879 07 2008 SXY SAFETY SECTION...
Page 7: ...S 4 Part 1167879 07 2008 FIGURE 1...
Page 12: ...S 9 Part 1167879 07 2008 FIGURE 3 0 8 AMP FUSE 3 15 AMP FUSE...
Page 20: ...S 17 Part 1167879 07 2008 NOTES...
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 29: ...CL 1 Part 1167879 07 2008 SXY CLEANING INFORMATION SECTION...
Page 32: ...CL 4 Part 1167879 07 2008 NOTES...
Page 33: ...P 1 Part 1167879 08 2008 SXY VEC 15 4 PROGRAMMING SECTION...
Page 47: ...P 15 Part 1167879 08 2008 SXY40 Space to Sales Plan o gram SXY30 Space to Sales Plan o gram...
Page 48: ...P 16 Part 1167879 08 2008 SXY40 Space to Sales Plan o gram SXY30 Space to Sales Plan o gram...
Page 63: ...P 31 Part 1167879 08 2008 WIRING DIAGRAM...
Page 64: ...P 32 Part 1167879 08 2008 WIRING DIAGRAM CONT...
Page 65: ...P 33 Part 1167879 08 2008 CUSTOM SPACE TO SALES DIAGRAM...
Page 73: ...ST 1 Part 1167879 07 2008 SXY SHELVES TRAYS PARTS SECTION...
Page 75: ...ST 3 Part 1167879 07 2008 6 12 14 16 7 3 13 15 11 5 5 4 10 8 19 2 9 17 17 19 18...
Page 77: ...ST 5 Part 1167879 07 2008 NOTES...
Page 106: ...M 1 Part 1167879 07 2008 SXY MAINTENANCE SECTION...
Page 114: ...M 9 Part 1167879 07 2008 NOTES...
Page 115: ...T 1 Part 1167879 07 2008 SXY TROUBLESHOOTING SECTION...
Page 128: ...T 14 Part 1167879 07 2008 NOTES...