![background image](http://html1.mh-extra.com/html/sanden/vendo-vue-sxy-30/vendo-vue-sxy-30_manual_3859556126.webp)
T-12
Part #1167879 07/2008
ERROR
PROBABLE
CAUSE
CORRECTIVE
ACTION
V
endor accepts and credits money but does
not vend (does not indicate a sold-out).
Defective selection switch.
Replace switch.
Defective selection switch harness.
Repair or replace harness.
Defective controller board.
Replace board.
REFRIGERA
TION
Refrigeration unit will not run.
Defective temperature sensor
.
1. Check connection.
2. Replace temperature sensor
.
Defective control board.
Replace board.
Refrigeration unit will not run at all.
No power to vendor
.
Check power supply
, also check service cord connections.
Unit will only run in the compressor relay test
mode.
(Located
under
T
est
Mode)
Defective cabinet switch.
Open and close the door to make sure lights and fan come on. If not, then
check the cabinet switch.
Defective temperature sensor
.
Follow the same steps detailed above about the temperature sensor
.
W
ait the 3 minute delay once the cabinet door is
closed.
W
ait to see if unit comes on.
Defective control board.
If unit still does not come on, then replace the control board.
Unit will not run in the compressor relay test
mode.
**NOTE:
Leave
the
compressor
relay
test mode on, in order to check for voltage.
Defective control board.
Unplug unit at power distibution panel. Remove air dam. Reconnect power
.
Enable compressor relay through
T
est Mode. Check 2-pin connection on
power distribution for 1
10V
.
Defective relay
.
Upon opening the cabinet door
, the lights and fans should shut of
f. If they
don’t, replace the cabinet switch.
Refrigeration unit runs constantly
.
Defective cabinet switch.
Upon opening the door
, the display should read either errors, summary
sales, or none. If it does not, then replace the cabinet switch.
Defective control board.
Replace control board.
Defective relay - contacts are welded together
.
Replace relay
.
Compressor will not start.
Overload protector inoperative.
Check overload (apply insulated jumper across terminal, if compressor
starts, replace overload).
Defective cabinet switch.
Check for error codes. Replace cabinet switch.
Compressor will not start, condenser
fan motor running - unit hot (power to
compressor).
Defective over load relay
Replace the over load relay
.
Compressor motor rocked
Replace the refer unit.
Defective capacitor
Replace the capacitor
.
Defective PTC relay
Replace the PTC relay
.
Compressor starts but does not run.
Loss
of
refrigerant
Replace the refrigeration unit.
Smashed tubings and capillary
Replace the refrigeration unit.
Defective over load relay
Replace the over load relay
.
Summary of Contents for Vendo Vue SXY 30
Page 1: ...i Part 1167879 07 2008 SXY TABLE OF CONTENTS...
Page 4: ...S 1 Part 1167879 07 2008 SXY SAFETY SECTION...
Page 7: ...S 4 Part 1167879 07 2008 FIGURE 1...
Page 12: ...S 9 Part 1167879 07 2008 FIGURE 3 0 8 AMP FUSE 3 15 AMP FUSE...
Page 20: ...S 17 Part 1167879 07 2008 NOTES...
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 29: ...CL 1 Part 1167879 07 2008 SXY CLEANING INFORMATION SECTION...
Page 32: ...CL 4 Part 1167879 07 2008 NOTES...
Page 33: ...P 1 Part 1167879 08 2008 SXY VEC 15 4 PROGRAMMING SECTION...
Page 47: ...P 15 Part 1167879 08 2008 SXY40 Space to Sales Plan o gram SXY30 Space to Sales Plan o gram...
Page 48: ...P 16 Part 1167879 08 2008 SXY40 Space to Sales Plan o gram SXY30 Space to Sales Plan o gram...
Page 63: ...P 31 Part 1167879 08 2008 WIRING DIAGRAM...
Page 64: ...P 32 Part 1167879 08 2008 WIRING DIAGRAM CONT...
Page 65: ...P 33 Part 1167879 08 2008 CUSTOM SPACE TO SALES DIAGRAM...
Page 73: ...ST 1 Part 1167879 07 2008 SXY SHELVES TRAYS PARTS SECTION...
Page 75: ...ST 3 Part 1167879 07 2008 6 12 14 16 7 3 13 15 11 5 5 4 10 8 19 2 9 17 17 19 18...
Page 77: ...ST 5 Part 1167879 07 2008 NOTES...
Page 106: ...M 1 Part 1167879 07 2008 SXY MAINTENANCE SECTION...
Page 114: ...M 9 Part 1167879 07 2008 NOTES...
Page 115: ...T 1 Part 1167879 07 2008 SXY TROUBLESHOOTING SECTION...
Page 128: ...T 14 Part 1167879 07 2008 NOTES...