T-3
Part #1167879 07/2008
The
SXY
30/40
vendor
provides
self-diagnostics
to
aid
you
in
the
trouble
shooting
process.
Error
codes
are
stored
in
the
controlle
r’
s
memory
when
a
system
error
is
sensed.
These
codes
can
be
accessed
in
the
Diagnostic
section
of
Programming.
The trouble shooting section contains Error Codes (version 15) and General Machine
T
roubleshooting.
Error Codes (version 15)
ERROR
DESCRIPTION OF
ERROR CODE
CHECKING METHOD
CORRECTIVE
ACTION
V
ending Mechanism - PDC Error (Hand Control Board)
X-motor Jam
X motor portion of vending
mechanism did not start or
complete.
System
Check:
If
unit
does
not
move,
check
the
LED
in
the
lower
left
hand
side
of
PDC.
It
should
be
a
constant
red
light.
If
LED
is not on, unplug machine, check fuse on power distribution
panel. Check two pin power connector in bottom of door
. Check
connection to board on X rail. Check power connection in PDC.
Check power supply connections in power distribution panel.
Check
LED
on
power
supply
in
power
distribution
panel.
Check
fuse on power supply in power distribution panel.
Replace fuse(s) if necessary
. Plug in machine. Complete a test vend
cycle.
If unit has not returned to the home position, check to see if hand
is jammed on tray or other item in cabinet.
Clear jam, unplug machine, wait 5 seconds and plug machine back in.
If hand goes back home after auto recovery
, run X motor in
T
est Motors.
Complete a test vend cycle. If hand does not go home in X, replace X
motor
.
If unit has returned to the home position, hand jammed but was
able to recover
. Check product positions to determine if any are
sold out with product still in column.
Complete a test vend cycle of sold out products. If hand hits tray in X,
adjust X home position.
Y
-motor Jam
Y
motor portion of vending
mechanism did not start or
complete.
Preform System Check, see X-Motor Jam.
Replace fuse(s) if necessary
. Plug in machine. Complete a test vend
cycle.
If unit has not returned to the home position, check to see if hand
is jammed on tray or other item in cabinet.
Clear jam, unplug machine, wait 5 seconds and plug machine back in.
If hand goes back home after auto recovery
, run
Y
motor in
T
est Motors.
Complete a test vend cycle. If hand does not go home in
Y
, replace
Y
motor
.
If unit has returned to the home position, hand jammed but was
able to recover
. Check product positions to determine if any are
sold out with product still in column.
Complete a test vend cycle of sold out products. If hand hits tray in
Y
,
run Discovery 2.
Z-motor Jam
Z motor portion of vending
mechanism did not start or
complete.
Preform System Check, see X-Motor Jam.
Replace fuse(s) if necessary
. Plug in machine. Complete a test vend
cycle.
If unit is extended in Z check Z housing ribbon cable to be sure it
is plugged in.
Unplug machine. Plug in Z housing ribbon cable. Plug machine back
in. If hand goes back home after auto recovery
, run Z motor in
T
est
Motors. Complete a test vend cycle.
If product is in hand, look to see if product is stopping the hand
from closing.
Remove product from hand. Unplug machine, wait 5 seconds and plug
machine back in. If hand goes back home after auto recovery
, run Z
motor in
T
est Motors. Complete a test vend cycle.
If unit has returned to the home position, hand jammed but was
able to recover
. Check product positions to determine if any are
sold out with product still in column.
Complete a test vend cycle of sold out products. If hand hits tray
front, run Discovery 2. If hand jams on center gate, reduce Z Product
Position by 3 encodings.
Clamp-motor Jam
Clamp motor portion of
vending mechanism did not
start or complete.
Preform System Check, see X-Motor Jam.
Replace fuse(s) if necessary
. Plug in machine. Complete a test vend
cycle.
Look
at
clamp
fingers
to
see
if
only
partially
open.
Clamp motor has failed. Replace clamp motor
.
Summary of Contents for Vendo Vue SXY 30
Page 1: ...i Part 1167879 07 2008 SXY TABLE OF CONTENTS...
Page 4: ...S 1 Part 1167879 07 2008 SXY SAFETY SECTION...
Page 7: ...S 4 Part 1167879 07 2008 FIGURE 1...
Page 12: ...S 9 Part 1167879 07 2008 FIGURE 3 0 8 AMP FUSE 3 15 AMP FUSE...
Page 20: ...S 17 Part 1167879 07 2008 NOTES...
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 29: ...CL 1 Part 1167879 07 2008 SXY CLEANING INFORMATION SECTION...
Page 32: ...CL 4 Part 1167879 07 2008 NOTES...
Page 33: ...P 1 Part 1167879 08 2008 SXY VEC 15 4 PROGRAMMING SECTION...
Page 47: ...P 15 Part 1167879 08 2008 SXY40 Space to Sales Plan o gram SXY30 Space to Sales Plan o gram...
Page 48: ...P 16 Part 1167879 08 2008 SXY40 Space to Sales Plan o gram SXY30 Space to Sales Plan o gram...
Page 63: ...P 31 Part 1167879 08 2008 WIRING DIAGRAM...
Page 64: ...P 32 Part 1167879 08 2008 WIRING DIAGRAM CONT...
Page 65: ...P 33 Part 1167879 08 2008 CUSTOM SPACE TO SALES DIAGRAM...
Page 73: ...ST 1 Part 1167879 07 2008 SXY SHELVES TRAYS PARTS SECTION...
Page 75: ...ST 3 Part 1167879 07 2008 6 12 14 16 7 3 13 15 11 5 5 4 10 8 19 2 9 17 17 19 18...
Page 77: ...ST 5 Part 1167879 07 2008 NOTES...
Page 106: ...M 1 Part 1167879 07 2008 SXY MAINTENANCE SECTION...
Page 114: ...M 9 Part 1167879 07 2008 NOTES...
Page 115: ...T 1 Part 1167879 07 2008 SXY TROUBLESHOOTING SECTION...
Page 128: ...T 14 Part 1167879 07 2008 NOTES...