51
Chapter 4 VRM AND EBL FUNCTION
4.3 EXAMPLE OF EBL FUNCTION
Example: EBL function.
Menu bar disappears after about 10 seconds.
How to change the EBL
Target bearing is displayed.
Flick on the screen, then the EBL line will move along
with the fingertip.
Turn the rotary knob to control the
movement of the EBL line.
Or
****
FOR REFERENCE
****
ABOUT EBL/VRM FUNCTION
The target position and range information can be measured by EBL and VRM function.
Bearing measurement method:
(1) The RELATIVE BEARING which is measured from own ship heading line.
(2) The ABSOLUTE BEARING which is measured from the north line.
Certainly, ABSOLUTE BEARING is calculated by RELATIVE BEARING and GYRO BEARING.
So, to calculate the ABSOLUTE BEARING is necessary a signal from GYRO or GPS compasses.
In case of no external bearing signal, display only RELATIVE BEARING mode.
Target tracking function (TT) and display AIS symbol is necessary the GYRO or GPS compass signal.
When GYRO or GPS compass signal is received, normally azimuth is measured from the north (ABSOLUTE AZIMUTH).
This radar scanner has a microwave BEAM WIDTH is about 5.2 degrees (NKE-1066) or 4 degrees (NKE2044).
So every target echo has more than 5.2 degrees or 4 degrees width for bearing direction.
For above reason, in case of read out the target azimuth, you need set EBL line to the center of the target echo.
RANGE of target echo in any azimuth can be measured by the VRM function from own ship.
Target echo size is proportion to pulse length which transmitted from own ship.
In case of MEASURE SHORT RANGE ECHO using VRM, you need set r
ing to the echo’s nearest point from own ship.
At that point, you can get the correct RANGE for any pulse length.
Summary of Contents for SMR-715 series
Page 1: ...MARINE RADAR EQUIPMENT INSTRUCTION MANUAL...
Page 2: ......
Page 15: ...xiii EQUIPMENT APPEARANCE NKE 1066 SCANNER UNIT NKE 2044 SCANNER UNIT...
Page 29: ...Chapter 1 INSTALLATION 3 1 2 3 DIMENSIONAL DRAWING OF DISPLAY MOUNTING...
Page 30: ...Chapter 1 INSTALLATION 4...
Page 32: ...Chapter 1 INSTALLATION 6 DESKTOP MOUNTING TEMPLATE Note Please note the paper size 182 257...
Page 34: ...Chapter 1 INSTALLATION 8 FLUSH MOUNTING TEMPLATE Note Please note the paper size 182 257...
Page 43: ...Chapter 1 INSTALLATION 17 NKE 2044 2FT SCANNER Fig 1 3 6 3 Fig 1 3 6 4...
Page 47: ...Chapter 1 INSTALLATION 21 Fig 1 4 1 3...
Page 51: ...Chapter 1 INSTALLATION 25 Fig 1 4 2 3...
Page 157: ...131 Chapter 10 AFTER SALE SERVICE 10 4 RADAR FAILURE CHECK LIST SMR...
Page 159: ...133 Chapter 12 SPECIFICATIONS Chapter 12 SPECIFICATIONS...
Page 160: ...134 Chapter 12 SPECIFICATIONS 12 1 SCANNER DIMENSION 12 1 1 NKE 1066 4 40 RUBBER PLATE...
Page 161: ...135 Chapter 12 SPECIFICATIONS 12 1 2 NKE 2044...
Page 162: ...136 Chapter 12 SPECIFICATIONS 12 2 DISPLAY DIMENSION 12 2 1 SMR 715 720...
Page 163: ...137 Chapter 12 SPECIFICATIONS...
Page 172: ...APPENDIX A 1 APPENDIX NKE 1066 1 5FT SCANNER INTERCONNECTION DIAGRAM FIG A1...
Page 173: ...APPENDIX A 2 NKE 2044 2FT SCANNER INTERCONNECTION DIAGRAM FIG A2...
Page 174: ...APPENDIX A 3 SMR 715 720 DISPLAY UNIT INTER CONNECTION DIAGRAM FIG A3...
Page 175: ...APPENDIX A 4 SMR 715 720 PRIMARY POWER SUPPLY DIAGRAM FIG A4...
Page 176: ...APPENDIX A 5 SMR 715 720 INTERCONNECTION DIAGRAM FIG A5...
Page 177: ...APPENDIX A 6 MEMO...
Page 187: ...APPENDIX A 16 DECLARATION OF CONFORMITY...
Page 188: ...APPENDIX A 17...
Page 189: ...APPENDIX...
Page 191: ...Chapter 3 ADJUST THE RADAR ECHO A 2...
Page 192: ...Chapter 3 ADJUST THE RADAR ECHO...