Speed calibration Fig. L72
On this screen there are two alternatives:
1.
Direct encoding of a known value
2.
Automatic calibration by driving 100 meters.
Header height adjustment Fig. L73
On this screen you set the height at which the
hectare counting and the reel speed adjustment are
interrupted.
The height value can be entered directly to the
“Header up” box, or save the current table height
pressing “Save”.
The two top boxes are for recording current position
as the minimum or maximum header height
Test
The test program is a general tool covering all the
inputs and outputs.
The test menu has two alternatives:
Test inputs: Function of the sensors can be
checked by activating the sensor, and by
examining how the impulses increase or the
sensor status changes HI
LOW.
Test outputs: In the test output menu all outputs
can be activated by pressing the corresponding
soft key.
Settings menu shows also active and passive fault
codes of the engiune.
The self-diagnostics monitors different functions in
the engine giving a fault report in case of possible
disturbance.
Additionally in certain cases, it limits the engine power,
performing a so called delayed stopping or a so called
forced stopping. The code in the display tells the
cause as described on the last pages of the engine
manual.