![Sampo Rosenlew Comia c4 Instruction Book Download Page 122](http://html.mh-extra.com/html/sampo-rosenlew/comia-c4/comia-c4_instruction-book_805454122.webp)
– 120 –
S6
S7
Sensors of ELECTRICAL SPEEDOMETERS
The sensors of electrical speedometers (driving speed
as well as fan and cylinder speeds) are located in the
gearbox and at the ends of the respective shafts. To
guarantee the correct functioning of the sensor, make
sure that distance a between the sensor and the pulse
disc (or the gear) is 1+
- 0.5 mm. (Fig S6.) Make any
necessary adjustments by turning the sensor
¿
xing nuts.
The sensor must not touch the rotating pulse disc.
Max-
imum tightening torque 5 Nm.
The Rotation Sensors
The threshing monitor have rotation sensors located on
several shafts. The sensors are of the Hall type, which
require a magnet attached on a rotating shaft. This
sensor type does not require a particularly accurate
installation distance. A suitable distance ranges
between 3-8 mm. Fig, S7
The Approaching Sensor
The threshing monitor is equipped with a Reed type
detector to detect the cutting table height. The detector
is located at the top right of the crop elevator. It consists
of a sensor and a magnet attached on the crop elevator.
The sensor distance from the magnet shall range
between 3-8 mm. Fig S7
The Reel Rotation Sensor
The threshing monitor has a rotation sensor located
on the reel shaft. It consists of an inductive sensor and
a star plate attached on the shaft. The distance from
the sensor head
a
to the edge of the star plate shall be
1-1.5 mm. Fig S6
Summary of Contents for Comia c4
Page 2: ......
Page 16: ... 14 ...
Page 126: ... 124 C8 C8 C8 LUBRICATION DIAGRAM ...
Page 134: ... 132 M3 ...
Page 136: ... 134 M6 ...
Page 137: ... 135 M7 ...