![Sampo Rosenlew Comia c4 Instruction Book Download Page 114](http://html.mh-extra.com/html/sampo-rosenlew/comia-c4/comia-c4_instruction-book_805454114.webp)
– 112 –
R1
R2a
R2b
GEARS
GEARBOX (Fig. R1)
Change the oil every 600 h or once a year.
The oil is drained by unplugging oil drain A.
New oil is poured into
¿
ller B. The oil level shall be be-
tween the lower end of the
¿
ller dipstick and the marker
with the cap screwed on.
Used oil is problem waste, which shall be disposed of in
an appropriate manner.
Use an oil type in accordance with the oil table. Check
and clean, if necessary, the breather on the cover.
CLOSED FINAL DRIVES (Figs. R2a and
R2b) on Models Equipped with Them
Change the oil every 1200 h or at least every other
year. The oil is drained by unplugging oil drain A.
Clean the bottom plug magnet.
New oil is poured in through a funnel into
¿
ller B at level
with rim C.
Used oil is problem waste, which shall be disposed of in
an appropriate manner.
Use an oil type in accordance with the oil table.
Check and clean, if necessary, breather C in the upper
section of the
¿
nal drive.
Depending on the type of
¿
nal drives, the plugs are po-
sitioned as shown in
¿
gures R2a and R2b.
Summary of Contents for Comia c4
Page 2: ......
Page 16: ... 14 ...
Page 126: ... 124 C8 C8 C8 LUBRICATION DIAGRAM ...
Page 134: ... 132 M3 ...
Page 136: ... 134 M6 ...
Page 137: ... 135 M7 ...