– 104 –
P56
Changing of CHOPPER KNIVES
If the rotor knives (or knife) are worn, they can be in-
verted. Broken or damaged knives must be replaced.
To maintain the rotor balance, it is important always to
change the two opposite knives as well.
To remove a knife, unscrew locknut A,
¿
g. P56. Now remove the
¿
xing screw
from the joint, which will disassemble
the joint.
Counter knives are fastened with a locking rod, which
is pulled out before changing the knives.