34 - 104
Function Parameters
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
torque boost is valid, but over this frequency point, the
torque boost is invalid.
The setting range of P04.01:0.0%:(automatic) 0.1%~10.0%
The setting range of P04.02: 0.0%~50.0%
P04.03
Motor V/F
frequency point
1
When P04.00 =1, the user can set V/F curve through
P04.03~P04.08.
V/F is generally set according to the load of the motor.
Note: V1
<
V2
<
V3, f1
<
f2
<
f3. Too high low frequency
voltage will heat the motor excessively or damage.
Overcurrent stall or overcurrent protection may occur.
The setting range of P04.03: 0.00Hz~P04.05
The setting range of P04.04, P04.06 and P04.08 :
0.0%~110.0% (rated motor voltage)
The setting range of P04.05: P04.03~ P04.07
The setting range of P04.07: P04.05~P02.02 (the rated
frequency of motor)
0.00Hz
○
P04.04
Motor V/F
voltage
point 1
00.0%
○
P04.05
Motor V/F
frequency point
2
00.00Hz
○
P04.06
Motor V/F
voltage point 2
00.0%
○
P04.07
Motor V/F
frequency point
3
00.00Hz
○
P04.08
Motor V/F
voltage point 3
00.0%
○