background image

With the aim of reducing the risk of severe bodily injury, 

including the injection of products or injuries caused by 

moving parts of the equipment or electric shock, the 

procedure described below must be followed as soon as the 

system is halted, during assembly, cleaning or changing the 

cap and also when spraying is interrupted.
1) Set the gun safety catch.
2) With the equipment, pressurized hose and gun, turn the 

pressure regulator (nº 5, Fig. 1) for the equipment to the 

minimum setting (anticlockwise).

3) Remove the spray gun safety catch. Holding a metallic 

part of the spray gun to the side of a correctly-grounded 

bucket, press the trigger to drain the product (aim the jet 

toward the side of the bucket) until gauge (No 7 Fig.1) 

indicate "0". 
4) Set the gun safety catch.
5) Open the product return key (No 4 Fig.1).
6) Turn the pressure regulator (No. 5 fig.1) clockwise until 

the product FLOWS SMOOTHLY through the product return 

Hose (No. 3 fig.1)

-  16  -

Before each start-up and especially after cleaning or repairing 

the unit, a check must be made that all its elements are 

securely tightened.
The first time you use your equipment there is no need to 

depressurise it, as it is already supplied in a totally 

depressurised state, though it will be necessary to do this 

each time any maintenance or repair work is carried out.
Should this safety measure not be observed, this may lead 

to malfunctions, personal injury and accidents, which may 

prove to be fatal. SAGOLA S.A. does not accept any 

responsibility for the consequences of any non-compliance 

with these safety regulations
Before starting up the equipment, proceed according to the 

points given below, in the order in which they are indicated 

(if all the specified steps are followed on shutting down the 

equipment, it will be in the status referred to below):
1.- Open the product decompression valve (nº4 fig.1), to 

drain the equipment.
2.- Set the pressure regulator (nº5, fig.1) to the minimum 

position (turn anticlockwise).
3.- Check the product circuit for loose connections.
4.- Remove the product cap from the gun.
5.- Empty the cleaning solvent present in the interior of the 

pump, by means of the drain tube (nº3 fig.1). To do this, set 

the motor start-up switch to ON. Turn the regulator (nº5  fig.1) 

gently to the right. Within a few seconds solvent will begin 

to run from drain tube (nº3 fig.1).
Collect the solvent issuing from the drain tube in a container.

As soon as no more solvent runs out, turn the pressure 

regulator to the minimum setting (anticlockwise) and 

disconnect the motor by means of the switch (to the setting

“off”).
6.- Insert the suction probe (nº2 fig. 1) into the paint tank. If 

the pump has a gravity tank, fill this tank (in accordance with 

the quantity required for use). Place the drain tube in the 

paint container or in the gravity tank (nº1 fig.1).
7.- Set the motor switch (nº8 fig.1) to the ON position. Turn 

the pressure regulator (nº5 fig.1) gently to the right. Within 

a few seconds product will run from the drain tube (nº3 fig.1). 
Move the pressure regulator again, to the minimum setting. 

Close the drain tube stopcock (nº4 fig.1). 
8.- Aim the gun towards a properly-grounded container. 

Press the trigger on the gun, holding a metallic part of the 

gun (the hand protector, for instance) in contact with the 

metallic container. Start turning the pressure regulator once 

again (nº5 fig.1) gently to the right. Within a few seconds, 

product will flow from the head of the gun which is not fitted 

with a cap. Maintain the flow of product until this is even (no 

air) from the head. Turn pressure regulator (nº5 Fig.1) to the 

minimum position. Release the gun trigger and place 

insurance.
9.- Install the spray cap.
10.- Adjust the spray width:
- Increase the pressure by means of the pressure regulator 

(nº5, fig.1) until the product flowing from the gun is fully 

atomised. To avoid spraying too great a quantity of product, 

which may lead to excessive mist and premature wear on 

the cap and other parts of the equipment, always use the 

lowest pressure setting possible to obtain the performance 

and thickness in microns given by the manufacturer of the 

product.
- Once the atomising pressure for the product has been 

determined, if a greater quantity of product is required, it is 

preferable to use a cap of greater diameter than to increase 

the pressure during application.
- To set the shape of the spray width, set the spray gun safety 

catch, loosen the cap attachment bolt and turn to the desired 

direction. Tighten the cap attachment bolt.

8. START-UP

SAGOLA S.A. has service Kits for the repair and replacement of consumable components in the unit, indicated in the exploded 

view sheets.
Ref. 30090021  Non return valve (nº11spare part list)

Ref. 56418599  Diaphragm kit + oil kit (nº22 + nº27 spare part list)

Ref. 30090091  Product tank (nº8 spare part list)

Ref. 86464701  Pressure Regulator Kit (nº24 spare part list)

Ref. 87560003  Absorption valve (nº19 spare part list)

7. SERVICE KITS

9. DEPRESSURISATION

Summary of Contents for 30941201

Page 1: ...a n u a l d e i n s t r u c c i o n e s l i s t a d e r e p u e s t o s i n s t r u c t i o n m a n u a l s p a r e p a r t s l i s t m a n u a l d e i n s t r u e s d e s m o n t a g e m d e p e a s...

Page 2: ......

Page 3: ...esta en marcha p g 6 9 Despresurizaci n p g 6 10 Funcionamiento p g 7 11 Parada p g 7 11 1 Parada de corta duraci n p g 7 11 2 Parada con finalizaci n de trabajo p g 7 12 Limpieza p g 8 13 Mantenimien...

Page 4: ...ter M nimo 0 65 L M ximo 0 75 L Presi n de trabajo 0 160 bar 0 2 400 psi Caudal libre 2 L min viscosidad agua 0 52 gal min Entrada de producto Rosca m trica redonda 36 x 2 macho Salida de producto Ros...

Page 5: ...r el equipo a una toma de tierra para eliminar la electricidad est tica La resistencia derivadora total de la l nea debe ser 1 mill n de ohmios El equipo est preparado para tener una larga vida siendo...

Page 6: ...alir producto por el tubo de purga n 3 fig 1 en el caso de la versi n de dep sito Accionar de nuevo el regulador para colocarlo en su posici n m nima Cerrar la llave de paso n 4 fig 1 del tubo de purg...

Page 7: ...si n mas baja posible para obtener los rendimientos y micrajes expresados por el fabricante del producto con mayores presiones de pulverizaci n NO se realizan mejores acabados y en cambio s se consigu...

Page 8: ...Cuando salga el disolvente por la Tuber a de retorno de producto n 3 fig 1 cierre la llave de retorno n 4 fig 1 4 Accione suavemente el mando del regulador de presi n n 5 fig 1 para regular la presi n...

Page 9: ...9 4 58 50850703 2 59 80860501 2 60 57450911 4 61 86260302 2 62 85762133 2 63 80860402 4 64 86260002 2 65 57251012 4 66 80860504 4 67 84260009 1 68 87660203 1 69 55710005 1 01 82460077 1 02 85760306 1...

Page 10: ...ro para el usuario o las personas que se hallen pr ximas como consecuencia de escapes roturas etc El equipo est preparado para su uso a temperatura ambiente La temperatura m xima de servicio es de 50...

Page 11: ...do La V lvula de absorci n est deteriorada La Pistola carece de Boquilla de Pulverizaci n El Filtro de producto de la Pistola est obturado La Boquilla de Pulverizaci n de la pistola est deteriorada El...

Page 12: ...o Sale aceite por la pistola o purga El motor se calienta en exceso El equipo toma excesiva presi n El Filtro de producto de la Pistola est obturado La Boquilla de Pulverizaci n de la pistola est atas...

Page 13: ...vice Kits page 16 8 Start up page 16 9 Depressurisation page 16 10 Operation page 17 11 Stopping page 17 11 1 Short stop page 17 11 2 Stopping when work is finished page 17 12 Cleaning page 18 13 Main...

Page 14: ...nsfer and excellent quality finish as well as low levels of contamination The equipment consists of the following standard features Pump model ATLANTA 200 PLUS Instruction manual Case As optional and...

Page 15: ...e the installation dangerous The total derivative resistance must be 1 million ohms The unit has been designed for long service and can be used with most products available on the market Its use with...

Page 16: ...from the drain tube in a container As soon as no more solvent runs out turn the pressure regulator to the minimum setting anticlockwise and disconnect the motor by means of the switch to the setting...

Page 17: ...ance and thickness in microns given by the manufacturer of the product 13 2 Once the atomising pressure for the product has been determined if a greater quantity of product is required it is preferabl...

Page 18: ...ked in thinner Keep gasket areas free of accretions and foreign bodies The air cap is a precision component Any deformation especially in the product outlet orifices may cause malfunctions in its oper...

Page 19: ...03 2 59 80860501 2 60 57450911 4 61 86260302 2 62 85762133 2 63 80860402 4 64 86260002 2 65 57251012 4 66 80860504 4 67 84260009 1 68 87660203 1 69 55710005 1 01 82460077 1 02 85760306 1 03 85760840 1...

Page 20: ...erous situations for the user or personnel standing near the unit as a consequence of leaks breakages etc The equipment has been designed for use at ambient temperature The maximum operating temperatu...

Page 21: ...fitted with a cap The gun filter is clogged The cap is worn The paint is too thick The material is too thick Insufficient pumping pressure The gun filter is clogged Check the power supply network Mak...

Page 22: ...the gun or drain The motor overheats The unit builds up too much pressure The product Filter is blocked The Aircap is blocked The purge stopcock is open or faulty The anti return valve is dirty or da...

Page 23: ...Arranque p g 26 9 Despressuriza o p g 26 10 Funcionamento p g 27 11 Parada p g 27 11 1 Parada de curta dura o p g 27 11 2 Parada com finaliza o de trabalho p g 27 12 Limpeza p g 28 13 Manuten o p g 28...

Page 24: ...a grande qualidade de acabamento com um n vel de polui o bastante baixo O equipamento de s rie est formado por Bomba modelo ATLANTA 200 PLUS Manual de instru es Recipiente Como elementos opcionais e c...

Page 25: ...Verifique periodicamente uma vez por semana sua continuidade el trica Caso sua resist ncia exceda os limites recomendados corrija a Um equipamento sem conex o ao terra ou com uma conex o mal feita pod...

Page 26: ...reita Dentro de poucos segundos produto ser executado a partir do dreno tubo n 3 Fig 1 Mova o regulador de press o novamente para a configura o m nima 8 Aponte a pistola para um recipiente devidamente...

Page 27: ...as pelo fabricante do produto com press es de pulveriza o maiores N O melhores acabamentos s o feitos e em vez disso se voc fica menos pior desempenho e transfer ncia do produto 13 2 Depois de determi...

Page 28: ...uza a tubula o de retorno do produto n 3 fig 1 2 Desligue o motor operando o interruptor de alimenta o No 8 Fig 1 3 Quando o solvente sair pela tubula o de retorno do produto n 3 fig 1 feche a chave d...

Page 29: ...7450909 4 58 50850703 2 59 80860501 2 60 57450911 4 61 86260302 2 62 85762133 2 63 80860402 4 64 86260002 2 65 57251012 4 66 80860504 4 67 84260009 1 68 87660203 1 69 55710005 1 01 82460077 1 02 85760...

Page 30: ...inar situa es de perigo para o usu rio ou para as pessoas que se encontrem nas imedia es em decorr ncia de escapamentos rupturas etc Aequipamento est preparado para ser usado temperatura ambiente A te...

Page 31: ...lvula de suc o est danificada A pistola n o tem bocal de pulveriza o O filtro do producto da pistola est obturado O bocal de pulveriza o da pistola est danificado Aviscosidade do pintura excessivamen...

Page 32: ...o e calibra o do regulador Verifique a tens o de entrada para o motor Colocar el equipo en un lugar en el que no se impida la aspiraci n de aire por parte del ventidalor Mudan a de rolamentos ou motor...

Page 33: ...at Kaufdatum Data de Compra Data di aacquisto E mail Tel Fax Sello Stamp Cachet Stempel Selo Timbro GUARANTEE C0NDITIONS CONDITIONS DE GARANTIE CONDICIONES DE GARANT A CONDI ES DA GARANTIA CONDIZIONI...

Page 34: ......

Page 35: ......

Page 36: ...CHER DIENST PROFESSIONNELLE REPARATURGARANTIE SERVI O DE ASSIST NCIA T CNICA GARANT A DE REPARA AO PROFISSIONAL SERVIZIO DI ASSISTENZA TECNICA GARANZIA DI RIPARAZIONE PROFESSIONALE Tel 34 945 214 150...