background image

4. COMPONENTS

- Before putting the unit into operation, and especially after 

each cleaning and/or repair operation, a check must be made 

that the equipment components are securely tightened and 

that the hoses are airtight (no leaks). Faulty parts must be 

replaced or repaired as appropriate.
- The Unit is easy to handle thanks to its design and the 

simplicity of its mechanisms. No special training is required 

for handling the unit. This team is professional use only. Use 

it according to the operating, maintenance and safety 

instructions indicated in this manual and follow the application 

methods indicated to obtain the required quality of finish.
- Before putting the unit into operation, we recommend that 

you clean the equipment as this has been subjected to 

functional tests and before packaging it is treated internally 

with a protective coating, some of which may still remain. 

Apply thinner to eliminate this. Remove any residual grease 

applied during assembly.
- The unit is depressurised when supplied (no pressure 

inside).
- Ensure that the products to be applied are chemically 

compatible with the components these come into contact 

with (aluminium, stainless steel, polyethylene and acetal 

resin).
- Do not use corrosive or abrasive products.
- Use SAGOLA anti-static hoses suited to the product to be 

transferred.

- You must always connect the equipment and all the 

elements involved in the work process to a grounding 

connection to eliminate static electricity. If its resistance 

exceeds the recommended limits, it must be fixed. An 

equipment unit without or with a faulty grounding connection 

may make the installation dangerous.
- The total derivative resistance must be ≤1 million ohms.
The unit has been designed for long service and can be 

used with most products available on the market. Its use 

with highly aggressive products will quickly increase the 

need for maintenance and spare parts. If you need to apply 

special products, please contact SAGOLA S.A.
- Read and apply all the information, instructions and safety 

measures indicated by the manufacturer of the products to 

be applied (products to be applied, thinners, etc.) as these 

may provoke chemical reactions, fires and/or explosions, or 

be toxic, irritant or harmful and in all cases dangerous for 

the health and personal safety of the user and of other 

persons nearby (see chapter on Health and Safety).
- Mix, prepare and filter the product to be applied in 

accordance with the manufacturer's instructions, ensuring 

that any foreign bodies are prevented from spoiling the quality 

of finish and application. Should there be any doubt related 

to the purity of the product, its composition, etc. please 

contact your supplier.
- Control the viscosity of the product to be applied with the 

SAGOLA Viscosimeter kit- Code 564 180 01.

5. WARNINGS

The ATLANTA 200 PLUS equipment can be used to apply 

medium viscosity products, commonly used in the sectors 

of construction, automotive, Wood Industry, Plastic, etc.
The product to be applied (Varnishes, backgrounds, primers, 

enamels and varnishes, etc.) is introduced into the gravity 

tank.

From the cup it is fed by gravity to the interior of the unit.
From the unit, through the product hose and the gun, the 

product is sprayed

6. FUNCTIONAL DESCRIPTION OF THE EQUIPMENT

-  15  -

1  

Product Cup

2  

Product return hose

Product return key

4  

Pressure Regulator

5  

Product Outlet

6  

Pressure Gauge

Electrical switch

4

1

7

2

3

5

6

Summary of Contents for 30941201

Page 1: ...a n u a l d e i n s t r u c c i o n e s l i s t a d e r e p u e s t o s i n s t r u c t i o n m a n u a l s p a r e p a r t s l i s t m a n u a l d e i n s t r u e s d e s m o n t a g e m d e p e a s...

Page 2: ......

Page 3: ...esta en marcha p g 6 9 Despresurizaci n p g 6 10 Funcionamiento p g 7 11 Parada p g 7 11 1 Parada de corta duraci n p g 7 11 2 Parada con finalizaci n de trabajo p g 7 12 Limpieza p g 8 13 Mantenimien...

Page 4: ...ter M nimo 0 65 L M ximo 0 75 L Presi n de trabajo 0 160 bar 0 2 400 psi Caudal libre 2 L min viscosidad agua 0 52 gal min Entrada de producto Rosca m trica redonda 36 x 2 macho Salida de producto Ros...

Page 5: ...r el equipo a una toma de tierra para eliminar la electricidad est tica La resistencia derivadora total de la l nea debe ser 1 mill n de ohmios El equipo est preparado para tener una larga vida siendo...

Page 6: ...alir producto por el tubo de purga n 3 fig 1 en el caso de la versi n de dep sito Accionar de nuevo el regulador para colocarlo en su posici n m nima Cerrar la llave de paso n 4 fig 1 del tubo de purg...

Page 7: ...si n mas baja posible para obtener los rendimientos y micrajes expresados por el fabricante del producto con mayores presiones de pulverizaci n NO se realizan mejores acabados y en cambio s se consigu...

Page 8: ...Cuando salga el disolvente por la Tuber a de retorno de producto n 3 fig 1 cierre la llave de retorno n 4 fig 1 4 Accione suavemente el mando del regulador de presi n n 5 fig 1 para regular la presi n...

Page 9: ...9 4 58 50850703 2 59 80860501 2 60 57450911 4 61 86260302 2 62 85762133 2 63 80860402 4 64 86260002 2 65 57251012 4 66 80860504 4 67 84260009 1 68 87660203 1 69 55710005 1 01 82460077 1 02 85760306 1...

Page 10: ...ro para el usuario o las personas que se hallen pr ximas como consecuencia de escapes roturas etc El equipo est preparado para su uso a temperatura ambiente La temperatura m xima de servicio es de 50...

Page 11: ...do La V lvula de absorci n est deteriorada La Pistola carece de Boquilla de Pulverizaci n El Filtro de producto de la Pistola est obturado La Boquilla de Pulverizaci n de la pistola est deteriorada El...

Page 12: ...o Sale aceite por la pistola o purga El motor se calienta en exceso El equipo toma excesiva presi n El Filtro de producto de la Pistola est obturado La Boquilla de Pulverizaci n de la pistola est atas...

Page 13: ...vice Kits page 16 8 Start up page 16 9 Depressurisation page 16 10 Operation page 17 11 Stopping page 17 11 1 Short stop page 17 11 2 Stopping when work is finished page 17 12 Cleaning page 18 13 Main...

Page 14: ...nsfer and excellent quality finish as well as low levels of contamination The equipment consists of the following standard features Pump model ATLANTA 200 PLUS Instruction manual Case As optional and...

Page 15: ...e the installation dangerous The total derivative resistance must be 1 million ohms The unit has been designed for long service and can be used with most products available on the market Its use with...

Page 16: ...from the drain tube in a container As soon as no more solvent runs out turn the pressure regulator to the minimum setting anticlockwise and disconnect the motor by means of the switch to the setting...

Page 17: ...ance and thickness in microns given by the manufacturer of the product 13 2 Once the atomising pressure for the product has been determined if a greater quantity of product is required it is preferabl...

Page 18: ...ked in thinner Keep gasket areas free of accretions and foreign bodies The air cap is a precision component Any deformation especially in the product outlet orifices may cause malfunctions in its oper...

Page 19: ...03 2 59 80860501 2 60 57450911 4 61 86260302 2 62 85762133 2 63 80860402 4 64 86260002 2 65 57251012 4 66 80860504 4 67 84260009 1 68 87660203 1 69 55710005 1 01 82460077 1 02 85760306 1 03 85760840 1...

Page 20: ...erous situations for the user or personnel standing near the unit as a consequence of leaks breakages etc The equipment has been designed for use at ambient temperature The maximum operating temperatu...

Page 21: ...fitted with a cap The gun filter is clogged The cap is worn The paint is too thick The material is too thick Insufficient pumping pressure The gun filter is clogged Check the power supply network Mak...

Page 22: ...the gun or drain The motor overheats The unit builds up too much pressure The product Filter is blocked The Aircap is blocked The purge stopcock is open or faulty The anti return valve is dirty or da...

Page 23: ...Arranque p g 26 9 Despressuriza o p g 26 10 Funcionamento p g 27 11 Parada p g 27 11 1 Parada de curta dura o p g 27 11 2 Parada com finaliza o de trabalho p g 27 12 Limpeza p g 28 13 Manuten o p g 28...

Page 24: ...a grande qualidade de acabamento com um n vel de polui o bastante baixo O equipamento de s rie est formado por Bomba modelo ATLANTA 200 PLUS Manual de instru es Recipiente Como elementos opcionais e c...

Page 25: ...Verifique periodicamente uma vez por semana sua continuidade el trica Caso sua resist ncia exceda os limites recomendados corrija a Um equipamento sem conex o ao terra ou com uma conex o mal feita pod...

Page 26: ...reita Dentro de poucos segundos produto ser executado a partir do dreno tubo n 3 Fig 1 Mova o regulador de press o novamente para a configura o m nima 8 Aponte a pistola para um recipiente devidamente...

Page 27: ...as pelo fabricante do produto com press es de pulveriza o maiores N O melhores acabamentos s o feitos e em vez disso se voc fica menos pior desempenho e transfer ncia do produto 13 2 Depois de determi...

Page 28: ...uza a tubula o de retorno do produto n 3 fig 1 2 Desligue o motor operando o interruptor de alimenta o No 8 Fig 1 3 Quando o solvente sair pela tubula o de retorno do produto n 3 fig 1 feche a chave d...

Page 29: ...7450909 4 58 50850703 2 59 80860501 2 60 57450911 4 61 86260302 2 62 85762133 2 63 80860402 4 64 86260002 2 65 57251012 4 66 80860504 4 67 84260009 1 68 87660203 1 69 55710005 1 01 82460077 1 02 85760...

Page 30: ...inar situa es de perigo para o usu rio ou para as pessoas que se encontrem nas imedia es em decorr ncia de escapamentos rupturas etc Aequipamento est preparado para ser usado temperatura ambiente A te...

Page 31: ...lvula de suc o est danificada A pistola n o tem bocal de pulveriza o O filtro do producto da pistola est obturado O bocal de pulveriza o da pistola est danificado Aviscosidade do pintura excessivamen...

Page 32: ...o e calibra o do regulador Verifique a tens o de entrada para o motor Colocar el equipo en un lugar en el que no se impida la aspiraci n de aire por parte del ventidalor Mudan a de rolamentos ou motor...

Page 33: ...at Kaufdatum Data de Compra Data di aacquisto E mail Tel Fax Sello Stamp Cachet Stempel Selo Timbro GUARANTEE C0NDITIONS CONDITIONS DE GARANTIE CONDICIONES DE GARANT A CONDI ES DA GARANTIA CONDIZIONI...

Page 34: ......

Page 35: ......

Page 36: ...CHER DIENST PROFESSIONNELLE REPARATURGARANTIE SERVI O DE ASSIST NCIA T CNICA GARANT A DE REPARA AO PROFISSIONAL SERVIZIO DI ASSISTENZA TECNICA GARANZIA DI RIPARAZIONE PROFESSIONALE Tel 34 945 214 150...

Reviews: