- 16 -
Electric motor
Voltage
Frecuency
Power
Consumption
Power cord length
Earthed plug
Minimun section
Sump oil
Sump capacity
Adjustable pressure
Free flow
Product inlet
Product outlet
Max. tip recommended
Max. tip recommended with 2 guns
Gross weight
Dimensions
Approvals
Single phase. Switch with heat protection
220 volts
50 Hz
3 meters
3 x 2.5 m
2
Renolin MR-10
1,400 w (2 H.P.)
9.8 A
2,000 w (2.7 H.P.)
14.5 A
0.026”
0.016”
53 Kg.
600 x 450 x 600 mm.
0.032”
0.026”
72 Kg.
1,100 x 750 x 900 mm.
Min. 1.5 L - Max. 2.4 L
Min. 2.0 L - Max. 2.4 L
4.5 L/min.
(water viscosity)
7.5 L/min.
(water viscosity)
0 - 220 Bar
Metric thread 36 x 2 Male
Thread GAS 1/4 BSP Male
1. WARNING
2. INTRODUCTION
Equipment provided with an electric motor that activates the
hydraulic device which provides the pressure necessary to
spray the product.
The unit can be supplied:
- With a suction probe, which is inserted directly in the
container of the product to be applied.
3. TECHNICAL DETAILS
ATLANTA 500
ATLANTA 800
Before starting the unit you must read, take into considera-
tion and comply with all the indications described in this
Manual.
This manual must be kept in a safe place, accessible to all
users of the unit.
The unit must be started and handled exclusively by
personnel instructed in its use and must be employed only
for the purpose for which it was designed.
Likewise, accident prevention standards, work centre
regulations and directives and current legislation and
restrictions must be taken into consideration at all times.
SAGOLA S.A., the SAGOLA logotypes and other SAGOLA
products mentioned in this manual are registered trade-
marks or brand names of the company SAGOLA S.A.
This unit belongs to the family of devices designed to spray
products with high pressure electrically which is used for
the airless spraying (airless) various coating materials,
operated by means of a spray gun. They provide a high
level of product transfer and excellent quality finish, as well
as low levels of contamination.
The equipment consists of the following standard features:
- Pump model ATLANTA 500 / ATLANTA 800
- Instruction manual
- Case
As optional and complementary elements of the equip-
ment, in this Manual the following are included:
- Product hoses
- Airless Gun
- Spray air caps:
- Fixed Spray Fan
- Rotational (Self-cleaning)