background image

18. TROUBLESHOOTING

Failure 

Cause of the failure 

Repair

The equipment does not 
start up

The equipment does not 
absorb product

The equipment sucks but 
does not reach the 
required pressure under 
load

Abnormal vibration in the  
output hose
The equipment absorbs 
product and generates 
pressure on closing the 
stopcock, but the pressure 
drops sharply when the 
trigger is pressed

Pronounces horns or 
stripes appear at the 
edges of the spray width 

Faulty power supply

Failure in the electric motor

Pressure in the equipment

The container of product for application is empty
The suction filter is clogged
The suction probe is loose, clogged or 
punctured
The pressure regulator is at the minimum setting
The drain stopcock is closed
The suction valve is jammed, dirty or damaged

The anti-return valve is jammed, dirty or 
damaged
The oil level in the housing is insufficient

The driving diaphragm is damaged
The hydraulic system is loose or faulty

The drain tube stopcock is open or damaged 
Insufficient oil level
Anti-return valve is damaged or dirty
Suction hose or filter is damaged or dirty
The diaphragm is punctured or broken
Air bubbles in the hydraulic system

Anti-return valve is damaged or dirty
Anti-return valve joint is damaged
Defective lower anti-return valve connection. 
The suction probe and/or suction filter are loose, 
dirty or damged
The suction probe is worn
The gun is not fitted with a cap
The gun filter is clogged
The cap is worn
The paint is too thick
The material is too thick
Insufficient pumping pressure

The gun filter is clogged
The suction probe and/or suction filter are loose, 
dirty or damged

Check the power supply network
Make sure the equipment is plugged into the 
power supply
Check that the motor switch is at the setting "on"
Faulty condenser in the motor
Faulty motor switch 
Check the plug and switch wiring
Eliminate pressure in the unit following the 
descompression procedure described on manual
Re-fill the container
Clean or replace
Check or replace the suction probe 
attachment bolt
Adjust th epressure regulator
Open the stopcock
Release the suction valve and clean or 
replace
Release anti-return valve and clean or  
replace
Replenish the housing with oil to the level 
indicated on the diptick
Replace the diaphragm
Disassemble as indicated in the appropriate 
section and check the piston, sleeve and 
hydraulic connections 
Close the stopcock or replace
Replenish
Clean or replace the valve
Clean or replace the valve
Replace the diaphragm
Adjust th eproduct regulator (Maximum 
-Minimum) to eliminate the air bubbles
Clean or replace the valve
Replace the joint
Replace the anti-return connection. Tighten 
the suction probe, and clean or replace the 
suction probe and the suction filter
Replace the suction probe 
Fit a cap
Clean or replace
Replace with a new cap
Dilute the paint with solvent
Dilute the product to the correct viscosity 
Turn the pressure regulator to increase the 
pumping pressure
Clean or replace
Tighten and/or clean or replace the suction 
probe and the suction filter

-  25  -

Summary of Contents for 30940801

Page 1: ...u a l d e i n s t r u c c i o n e s l i s t a d e r e p u e s t o s i n s t r u c t i o n m a n u a l s p a r e p a r t s l i s t m a n u a l d e i n s t r u e s d e s m o n t a g e m d e p e a s ATL...

Page 2: ......

Page 3: ...uesta en marcha p g 7 9 Despresurizaci n p g 7 10 Funcionamiento p g 8 11 Parada p g 8 11 1 Parada de corta duraci n p g 8 11 2 Parada con finalizaci n de trabajo p g 8 12 Limpieza p g 9 13 Mantenimie...

Page 4: ...junto a un muy bajo nivel de contaminaci n Equipo compuesto de serie por Bomba modelo ATLANTA 500 ATLANTA 800 Manual de Instrucciones Envase Como elementos opcionales y complementarios del equipo Mang...

Page 5: ...Tuber a de retorno del producto 4 Llave de retorno del producto 5 Regulador de Presi n 6 Salida de Producto 7 Man metro 8 Interruptor el ctrico 9 V vula antirretorno 10 V lvula 11 Tacos fabricados en...

Page 6: ...ante de los productos que vaya a utilizar productos a aplicar diluyentes etc ya que pueden generar reacciones qu micas incendios y o explosiones o ser t xicos irritantes o nocivos y en todo caso pelig...

Page 7: ...ubo de purga n 3 fig 1 Para ello accionar el interruptor de arranque del motor posici n de encendido Accionar el regulador n 5 fig 1 hacia la derecha suavemente En unos segundos empezara a salir disol...

Page 8: ...l producto atomiza si necesita aplicar mayor cantidad de producto recomendamos que preferentemente utilice una boquilla de mayor paso antes que aumentar la presi n de aplicaci n 13 3 Para conseguir la...

Page 9: ...terruptor el ctrico n 8 fig 1 3 Cuando salga el disolvente por la Tuber a de retorno de producto n 3 fig 1 cierre la llave de retorno n 4 fig 1 4 Accione suavemente el mando del regulador de presi n n...

Page 10: ...1 39 57250804 4 40 81560016 1 41 85760075 1 42 87260407 1 43 87261813 1 44 82560001 1 45 86060010 1 46 80860004 1 47 80660314 1 48 80660413 1 49 86060012 1 50 86464002 1 51 80660308 5 52 80860402 4 5...

Page 11: ...20 1 39 57250804 4 40 81560016 1 41 85760078 1 42 87260407 1 43 87260414 1 44 82560001 1 45 86060010 1 46 80860004 1 47 80660314 1 48 80660413 1 49 86060012 1 50 86464001 1 51 80660308 5 52 80860402 4...

Page 12: ...para el usuario o las personas que se hallen pr ximas como consecuencia de escapes roturas etc El equipo est preparado para su uso a temperatura ambiente La temperatura m xima de servicio es de 50 C L...

Page 13: ...est deteriorada La Pistola carece de Boquilla de Pulverizaci n El Filtro de producto de la Pistola est obturado La Boquilla de Pulverizaci n de la pistola est deteriorada El producto tiene viscosidad...

Page 14: ...o Sale aceite por la pistola o purga El motor se calienta en exceso El equipo toma excesiva presi n El Filtro de producto de la Pistola est obturado La Boquilla de Pulverizaci n de la pistola est atas...

Page 15: ...s page 18 8 Start up page 19 9 Depressurisation page 19 10 Operation page 20 11 Stopping page 20 11 1 Short stop page 20 11 2 Stopping when work is finished page 20 12 Cleaning page 21 13 Maintenance...

Page 16: ...d comply with all the indications described in this Manual This manual must be kept in a safe place accessible to all users of the unit The unit must be started and handled exclusively by personnel in...

Page 17: ...on Probe 3 Product return hose 4 Product return key 5 Pressure Regulator 6 Product Outlet 7 Pressure Gauge 8 Electrical switch 9 Non return valve 10 Valve 11 Tacks manufactured in duralumin 12 Polyami...

Page 18: ...es suited to the product to be transferred You must always connect the equipment and all the elements involved in the work process to a grounding connection to eliminate static electricity If its resi...

Page 19: ...mp by means of the drain tube n 3 fig 1 To do this set the motor start up switch to ON Turn the regulator n 5 fig 1 gently to the right Within a few seconds solvent will begin to run from drain tube n...

Page 20: ...o increase the pressure during application 13 3 To set the shape of the spray width set the spray gun safety catch loosen the cap attachment bolt and turn to the desired direction Tighten the cap atta...

Page 21: ...rom the gun hoses and the rest of the unit with a cloth soaked in thinner Keep gasket areas free of accretions and foreign bodies The air cap is a precision component Any deformation especially in the...

Page 22: ...0 1 39 57250804 4 40 81560016 1 41 85760075 1 42 87260407 1 43 87261813 1 44 82560001 1 45 86060010 1 46 80860004 1 47 80660314 1 48 80660413 1 49 86060012 1 50 86464002 1 51 80660308 5 52 80860402 4...

Page 23: ...320 1 39 57250804 4 40 81560016 1 41 85760078 1 42 87260407 1 43 87260414 1 44 82560001 1 45 86060010 1 46 80860004 1 47 80660314 1 48 80660413 1 49 86060012 1 50 86464001 1 51 80660308 5 52 80860402...

Page 24: ...erous situations for the user or personnel standing near the unit as a consequence of leaks breakages etc The equipment has been designed for use at ambient temperature The maximum operating temperatu...

Page 25: ...ilter is clogged The cap is worn The paint is too thick The material is too thick Insufficient pumping pressure The gun filter is clogged The suction probe and or suction filter are loose dirty or dam...

Page 26: ...tor Place the equipment in a location where the ventilator air intake is not impeded Replace the bearings or the motor Replace it Send the unit to the S A T SAGOLA In accordance with Directive 2006 42...

Page 27: ...rranque p g 31 9 Despressuriza o p g 31 10 Funcionamento p g 32 11 Parada p g 32 11 1 Parada de curta dura o p g 32 11 2 Parada com finaliza o de trabalho p g 32 12 Limpeza p g 33 13 Manuten o p g 33...

Page 28: ...amento leia atentamente tenha em conta e cumpra integralmente todas as indica es descritas neste manual Conserve o equipamento num lugar seguro e acess vel para todos os usu rios do mesmo O equipament...

Page 29: ...bsor o 3 Tubula o de retorno do produto 4 Chave de retorno do produto 5 Regulador de press o 6 Sa da de produto 7 Man metro 8 Chave el trica 9 V lvula anti retorno 10 V lvula 11 Tacos de duralum nio 1...

Page 30: ...cas Se for necess rio aplicar produtos especiais consulte a SAGOLA S A Leia e aplique com aten o todos os dados instru es e medidas de seguran a indicados pelo fabricante dos produtos que vai utilizar...

Page 31: ...para ON Rode o regulador n 5 Fig 1 suavemente para a direita Dentro de poucos segundos solvente come ar a correr a partir do tubo de drenagem n 3 Fig 1 Recolhe se o solvente a partir de emiss o do tu...

Page 32: ...o m ximo do produto recomenda se que de prefer ncia usar uma etapa principal do bocal em vez de aumentar a press o de aplica o 13 3 Para obter a forma desejada do ventilador operar a trava de seguran...

Page 33: ...a de suc o n 2 fig 1 e introduza a tubula o de retorno do produto n 3 fig 1 2 Desligue o motor operando o interruptor de alimenta o No 8 Fig 1 3 Quando o solvente sair pela tubula o de retorno do prod...

Page 34: ...360320 1 39 57250804 4 40 81560016 1 41 85760075 1 42 87260407 1 43 87261813 1 44 82560001 1 45 86060010 1 46 80860004 1 47 80660314 1 48 80660413 1 49 86060012 1 50 86464002 1 51 80660308 5 52 808604...

Page 35: ...82360320 1 39 57250804 4 40 81560016 1 41 85760078 1 42 87260407 1 43 87260414 1 44 82560001 1 45 86060010 1 46 80860004 1 47 80660314 1 48 80660413 1 49 86060012 1 50 86464001 1 51 80660308 5 52 8086...

Page 36: ...situa es de perigo para o usu rio ou para as pessoas que se encontrem nas imedia es em decorr ncia de escapamentos rupturas etc Aequipamento est preparado para ser usado temperatura ambiente A temper...

Page 37: ...anificados A v lvula de suc o est danificada A pistola n o tem bocal de pulveriza o O filtro do producto da pistola est obturado O bocal de pulveriza o da pistola est danificado Aviscosidade do pintur...

Page 38: ...do regulador Verifique a tens o de entrada para o motor Colocar el equipo en un lugar en el que no se impida la aspiraci n de aire por parte del ventidalor Mudan a de rolamentos ou motor Substituir En...

Page 39: ......

Page 40: ...CHER DIENST PROFESSIONNELLE REPARATURGARANTIE SERVI O DE ASSIST NCIA T CNICA GARANT A DE REPARA AO PROFISSIONAL SERVIZIO DI ASSISTENZA TECNICA GARANZIA DI RIPARAZIONE PROFESSIONALE Tel 34 945 214 150...

Reviews: